Literature DB >> 17669876

What is the optimal level of anticoagulation in adult patients receiving warfarin following implantation of a mechanical prosthetic mitral valve?

Andrew Bayliss1, Peter Faber, Joel Dunning, Andrew Ronald.   

Abstract

A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was what is the optimal target INR for warfarin therapy in patients who have undergone implantation of a prosthetic mechanical mitral heart valves? Altogether 894 papers were identified on Medline and 1235 on Embase using the reported search including all major international guidelines. Twelve papers and publications represented the best evidence on the topic. The author, journal, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses were tabulated. We conclude that after implantation of new generation prosthetic mechanical mitral valves, patients should receive warfarin to a target INR of 2.5-3.5. For older types of valve the target INR should be 3.5-4.5. Warfarin therapy should be administered to maintain stable INR values ensuring lowest possible variation in the intensity of anticoagulation. In selected patients with a history of thromboembolic disease and/or coronary artery disease warfarin therapy consideration should be given to supplementing warfarin with low-dose aspirin.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17669876     DOI: 10.1510/icvts.2007.152819

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  3 in total

1.  Achieved anticoagulation vs prosthesis selection for mitral mechanical valve replacement: a population-based outcome study.

Authors:  Thierry Le Tourneau; Vanessa Lim; Jocelyn Inamo; Fletcher A Miller; Douglas W Mahoney; Hartzell V Schaff; Maurice Enriquez-Sarano
Journal:  Chest       Date:  2009-05-29       Impact factor: 9.410

2.  Comparison of quality of life in patients who underwent mechanical mitral valve replacement: star GK vs SJM.

Authors:  Jiang-Shan Huang; Ning Xu; Kai-Peng Sun; Zhi-Nuan Hong; Liang-Wan Chen; Yur-Ren Kuo; Qiang Chen
Journal:  J Cardiothorac Surg       Date:  2020-01-07       Impact factor: 1.637

3.  Anesthetic management of a patient with prosthetic heart valve for non-cardiac surgery: A case report.

Authors:  Goneppanavar Umesh; Swati Verma; Kaur Jasvinder
Journal:  Cases J       Date:  2008-09-30
  3 in total