Literature DB >> 17669866

Contrast ultrasound imaging: the best method to detect type II endoleak during endovascular aneurysm repair follow-up.

Maria Fabrizia Giannoni1, Fabrizio Fanelli, Michele Citone, Maria Cristina Acconcia, Francesco Speziale, Bruno Gossetti.   

Abstract

OBJECTIVES: Type II endoleak is the most common complication after endovascular aneurysm repair and require close surveillance. Hence, the need to validate new techniques as alternative to helical CT-scan, the reference standard. The aim of this study is to evaluate the efficacy of Cadence Contrast Pulse Sequencing ultrasound technique with second generation contrast agents in detecting endoleaks, and to compare the results with data obtained from CTA.
METHODS: 30 patients with endovascular stent grafts, during their regular follow-up consisting in serial CT and ultrasound exams performed at discharge, at one and six months and at one year thereafter, previous informed consent, were enrolled in a prospectic double blind study design in order to compare triphasic helical CT-scan to another adjunctive ultrasound investigation (Cadence CPS technique with Sono Vue). No more than 15 days occurred between the two examinations. In the study were evaluated only data obtained from the comparison of the two concomitant investigations, independently from the follow-up. Variables analysed were changes in the maximum diameter of the aneurysmal sac, presence and type of endoleak, if detected. In the case of disagreement between the two diagnostic tools angiography was performed.
RESULTS: One patient dropped out because of violation of the study protocol (a stroke occurred in the time interval between the two investigations). Both exams visualised patency and proper graft placement in all the remaining patients. Aneurysmal diameters with both investigations overlapped (r(s):0.98). In 21 patients no endoleak was detected with a significant aneurysmal sac shrinkage (P<0.001). In seven patients both methods confirmed presence of endoleak. Ultrasonography detected all type of endoleaks, while CT-scan was uncertain in one. Moreover, in one patient CT-angiography showed an increased aneurysmal diameter without other evidence, while a contrast ultrasound investigation disclosed a type II low-flow endoleak, confirmed by angiography.
CONCLUSIONS: The Cadence Contrast Pulse Sequencing with echo contrast agent is an ultrasound technique that substantially improves the ultrasound diagnostic reliability.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17669866     DOI: 10.1510/icvts.2006.137265

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  7 in total

1.  Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair.

Authors:  Vitaliano Buffa; Antonio Solazzo; Valeria D'Auria; Alessandra Del Prete; Andrea Vallone; Monica Luzietti; Manuela Madau; Roberto Grassi; Vittorio Miele
Journal:  Radiol Med       Date:  2014-07-02       Impact factor: 3.469

Review 2.  Contrast-enhanced ultrasound (CEUS) versus computed tomography angiography (CTA) in detection of endoleaks in post-EVAR patients. Are delayed type II endoleaks being missed? A systematic review and meta-analysis.

Authors:  J Chung; A Kordzadeh; I Prionidis; Y Panayiotopoulos; T Browne
Journal:  J Ultrasound       Date:  2015-01-17

3.  Endovascular repair of abdominal aortic aneurysms in low surgical risk patients: an evidence update.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2010-01-01

4.  Role of multidetector CT angiography and contrast-enhanced ultrasound in redefining follow-up protocols after endovascular abdominal aortic aneurysm repair.

Authors:  R Motta; L Rubaltelli; R Vezzaro; V Vida; P Marchesi; R Stramare; A Zanon; M Battistel; M Sommavilla; D Miotto
Journal:  Radiol Med       Date:  2012-03-19       Impact factor: 3.469

Review 5.  A Narrative Review on Contrast-Enhanced Ultrasound in Aortic Endograft Endoleak Surveillance.

Authors:  Sriharsha Gummadi; John R Eisenbrey; Andrej Lyshchik
Journal:  Ultrasound Q       Date:  2018-09       Impact factor: 1.657

Review 6.  Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.

Authors:  Iosief Abraha; Maria Laura Luchetta; Rita De Florio; Francesco Cozzolino; Giovanni Casazza; Piergiorgio Duca; Basso Parente; Massimiliano Orso; Antonella Germani; Paolo Eusebi; Alessandro Montedori
Journal:  Cochrane Database Syst Rev       Date:  2017-06-09

Review 7.  Contrast-enhanced ultrasound after endovascular aortic repair-current status and future perspectives.

Authors:  Sasan Partovi; Mathias Kaspar; Markus Aschwanden; Charles Lopresti; Shivanshu Madan; Heiko Uthoff; Stephan Imfeld; Daniel Staub
Journal:  Cardiovasc Diagn Ther       Date:  2015-12
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.