Literature DB >> 17669486

The effect of gas plasma modification on platelet and contact phase activation processes.

Nicholas P Rhodes1, Darren J Wilson, Rachel L Williams.   

Abstract

Medical-grade polytetrafluoroethylene (PTFE), polydimethylsiloxane (PDMS), polyetherurethane (PEU) and ultrahigh molecular weight polyethylene (UHMWPE) were plasma treated with O2, Ar, N2 and NH3. Their surface properties were characterised using X-ray photoelectron spectroscopy (XPS), static secondary ion mass spectroscopy (SSIMS), atomic force microscopy (AFM) and dynamic contact angle (DCA) analysis. Platelet adhesion, aggregation, activation and release of microparticles were determined after contact with whole blood in a cone and plate viscometer. Activation of the coagulation system was quantified in a static environment using a partial thromboplastin time (PTT) assay. The chemical compositions of the untreated surfaces were found to be very similar to those of the bulk material except for PEU, whose surface was comprised almost entirely of soft ether segments. For all materials, the different plasma treatments resulted in moderate etching with the incorporation of functional groups and removal of side groups: defluorination, dehydrogenation, cleavage of methyl side groups and soft segments for PTFE, UHMWPE, PDMS and PEU, respectively. Consequently, plasma treatment resulted in increased wettability in all cases. Blood contact with the virgin materials resulted in activation of platelets and the clotting cascade. Plasma treatment resulted in a significant reduction in platelet adhesion for all materials and all treatments. In the case of PTFE and PEU, the activation status of these cells was also reduced. Plasma treatment of all materials reduced fluid-phase CD62P expression. Platelet aggregate size correlated well with degree of aggregate formation, but many treatments increased the degree of aggregation, as was the case for microparticle shedding. There was no correlation between CD62P expression, aggregate formation and platelet microparticle (PMP) shedding. It is concluded that despite incorporation of the same chemical groups, the pattern of response to blood in vitro is not the same across different polymers.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17669486     DOI: 10.1016/j.biomaterials.2007.07.008

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  3 in total

1.  Oxygen and nitrogen plasma hydrophilization and hydrophobic recovery of polymers.

Authors:  Ville Jokinen; Pia Suvanto; Sami Franssila
Journal:  Biomicrofluidics       Date:  2012-01-03       Impact factor: 2.800

2.  A one-step, tunable method of selective reactive sputter deposition as a wrinkling approach for silver/polydimethylsiloxane for electrically conductive pliable surfaces.

Authors:  Joel Y Y Loh; Ali Zeineddine; Moein Shayegannia; Robyn McNeil; Liam McRae; Nazir P Kherani
Journal:  Microsyst Nanoeng       Date:  2022-08-08       Impact factor: 8.006

3.  Non-thermal dielectric-barrier discharge plasma damages human keratinocytes by inducing oxidative stress.

Authors:  Ki Cheon Kim; Mei Jing Piao; Susara Ruwan Kumara Madduma Hewage; Xia Han; Kyoung Ah Kang; Jin Oh Jo; Young Sun Mok; Jennifer H Shin; Yeunsoo Park; Suk Jae Yoo; Jin Won Hyun
Journal:  Int J Mol Med       Date:  2015-11-09       Impact factor: 4.101

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.