Safety and acceptability of implantation of internal cardioverter-defibrillators under local anesthetic and conscious sedation.

David J Fox1, Neil C Davidson, Martin Royle, David H Bennett, Bernard Clarke, Clifford J Garratt, Mark C S Hall, Amir M Zaidi, Kay Patterson, Adam P Fitzpatrick.   

Abstract

BACKGROUND: Implantation and testing of implantable defibrillators (ICDs) using local anesthetic and conscious sedation is widely practiced; however, some centers still use general anesthesia. We assessed safety and patient acceptability for implantation of defibrillators using local anesthetic and conscious sedation.
METHODS: The records of 500 consecutive device implants from two UK cardiac centers implanted under local anesthetic and conscious sedation from January 1996 to December 2004 were reviewed. Procedure time, left ventricular ejection fraction (LVEF) sedative dosage (midazolam), analgesic dosage (fentanyl or diamorphine), requirement for drug reversal, and respiratory support were recorded. Patient acceptability of the procedure was also assessed.
RESULTS: Of 500 implants examined, 387 were ICDs, 88 were biventricular ICDs, and 25 were generator changes. Patients with biventricular-ICDs had significantly longer (mean +/- SD) procedure times 129.7 +/- 7.6 minutes versus 63.3 +/- 32.3 minutes; P < 0.0001 and lower LVEF 24.4 +/- 8.4% versus 35.7 +/- 15.4%; P < 0.0001. There were no differences in the doses (mean +/- SD) of midazolam 8.9 +/- 3.5 mg versus 8.0 +/- 3.1 mg; P = NS, diamorphine 4.3 +/- 2.0 mg versus 3.8 +/- 1.7 mg; P = NS or fentanyl 94.4 +/- 53.7 mcg versus 92.2 +/- 48.6 mcg; P = NS, between the two groups. There were no deaths or tracheal intubations in either group. Acceptability was available for 373 of 500 (75%) patients, 41 of 373 (11%) described "discomfort," but from these 41 patients only 14 of 373 (3.8%) declined a second procedure under the same conditions.
CONCLUSIONS: Implantation of defibrillators under local anesthetic and sedation is safe and acceptable to patients. General anesthesia is no longer routinely required for implantation of defibrillators.

Entities:  

Mesh:

Year:  2007        PMID: 17669082     DOI: 10.1111/j.1540-8159.2007.00797.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

Review 1.  [Implantation of cardioverter-defibrillators. How much anesthesia is necessary?].

Authors:  T Sellmann; M Winterhalter; U Herold; P Kienbaum
Journal:  Anaesthesist       Date:  2010-06       Impact factor: 1.041

Review 2.  Anesthetic Management In Electrophysiology Laboratory: A Multidisciplinary Review.

Authors:  Mustafa Yildiz; Hulya Yilmaz Ak; Dogac Oksen; Sinan Oral
Journal:  J Atr Fibrillation       Date:  2018-02-28

Review 3.  Sedation in the Electrophysiology Laboratory: A Multidisciplinary Review.

Authors:  Neal S Gerstein; Andrew Young; Peter M Schulman; Eric C Stecker; Peter M Jessel
Journal:  J Am Heart Assoc       Date:  2016-06-13       Impact factor: 5.501

4.  Pectoralis blocks for insertion of an implantable cardioverter defibrillator in two patients with Duchenne muscular dystrophy.

Authors:  Alexander B Froyshteter; Tarun Bhalla; Joseph D Tobias; Gregory S Cambier; Christopher T Mckee
Journal:  Saudi J Anaesth       Date:  2018 Apr-Jun

5.  Feasibility and safety of using local anaesthesia with conscious sedation during complex cardiac implantable electronic device procedures.

Authors:  Elif Kaya; Hendrik Südkamp; Julia Lortz; Tienush Rassaf; Rolf Alexander Jánosi
Journal:  Sci Rep       Date:  2018-05-08       Impact factor: 4.379