Literature DB >> 17665013

Concentric needle single fiber electromyography: normative jitter values on voluntary activated Extensor Digitorum Communis.

João Aris Kouyoumdjian1, Erik V Stålberg.   

Abstract

Single fiber electromyography (SFEMG) is the most sensitive clinical neurophysiological test for neuromuscular junction disorders, particularly myasthenia gravis. Normal values for jitter obtained with SFEMG electrode have been published, but there are few publications for concentric needle electrode (CNE). The aim of this study was to discuss the possibilities to analyse the jitter in CNE recordings and to get normal values of jitter for voluntary activated Extensor Digitorum Communis using disposable CNE. Fifty normal subjects were studied, 16 male and 34 female with a mean age of 37.1+/-10.3 years (19-55). The jitter values of action potentials pairs of isolated muscular fibers were expressed as the mean consecutive difference (MCD) after 20 analysed potential pairs. The mean MCD (n=50) obtained was 24.2+/-2.8 micros (range of mean values in each subject was 18-31). Upper 95% confidence limit is 29.8 micros. The mean jitter of all potential pairs (n=1000) obtained was 24.07+/-7.30 micros (range 9-57). A practical upper limit for individual data is set to 46 micros. The mean interpotential interval (MIPI) was 779+/-177 micros (range of individual mean values was 530-1412); there were no potentials with impulse blocking. The present study confirms that CNE is suitable for jitter analysis although certain precautions must be mentioned. Our findings of jitter values with CNE were similar to some other few reports in literature.

Entities:  

Mesh:

Year:  2007        PMID: 17665013     DOI: 10.1590/s0004-282x2007000300016

Source DB:  PubMed          Journal:  Arq Neuropsiquiatr        ISSN: 0004-282X            Impact factor:   1.420


  4 in total

1.  Application of futility analysis to refine jitter recordings in myasthenia gravis.

Authors:  Pushpa Narayanaswami; Norberto Pantoja-Galicia; Rebecca A Betensky; Seward B Rutkove
Journal:  Muscle Nerve       Date:  2012-04       Impact factor: 3.217

2.  Jitter Values on Voluntary Active Periocular Muscles of Healthy Subjects with Conventional (37 mm) Concentric Needle Electrode.

Authors:  Leyla Baysal Kiraç; Elif Kocasoy Orhan; Saygın Gönderten; Mehmet Barış Baslo; Ali Emre Öge
Journal:  Noro Psikiyatr Ars       Date:  2016-06-01       Impact factor: 1.339

3.  Concentric Needle Jitter in 97 Myasthenia Gravis Patients.

Authors:  João Aris Kouyoumdjian; Gabriel Pina Paiva; Erik Stålberg
Journal:  Front Neurol       Date:  2020-11-13       Impact factor: 4.003

4.  Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle.

Authors:  João Aris Kouyoumdjian; Carla Renata Graca
Journal:  Front Neurol       Date:  2022-07-22       Impact factor: 4.086

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.