Literature DB >> 17664860

Comparison of three measures of the ankle-brachial blood pressure index in a general population.

Cheng-Rui Pan1, Jan A Staessen, Yan Li, Ji-Guang Wang.   

Abstract

The ankle-brachial blood pressure index (ABI) predicts cardiovasular disease. To our knowledge, no study has compared manual ABI measurements with an automated electronic oscillometric method in a population sample. We enrolled 946 residents (50.8% women; mean age, 43.5 years) from 8 villages in JingNing County, Zhejiang Province, P.R. China. We computed ABI as the ratio of ankle-to-arm systolic blood pressures from consecutive auscultatory or Doppler measurements at the posterior tibial and brachial arteries. We also used an automated oscillometric technique with simultaneous ankle and arm measurements (Colin VP-1000). Mean ABI values were significantly higher on Doppler than auscultatory measurements (1.15 vs. 1.07; p<0.0001) with intermediate levels on oscillometric determination (1.12; p<0.0001 vs. Doppler). The differences among the three measurements were not homogeneously distributed across the range of ABI values. Doppler and oscillometric ABIs were similar below 1.0, whereas above 1.2 Doppler and auscultatory ABIs were comparable. In Bland and Altman plots, the correlation coefficient between differences in Doppler minus oscillometric ABI and ABI level was 0.21 (p<0.0001). The corresponding correlation coefficient for Doppler minus auscultatory ABI was -0.13 (p<0.0001). In conclusion, automated ABI measurements are feasible in large-scale population studies. However, the small differences in ABI values between manual and oscillometric measurements depend on ABI level and must be considered in the interpretation of study results.

Entities:  

Mesh:

Year:  2007        PMID: 17664860     DOI: 10.1291/hypres.30.555

Source DB:  PubMed          Journal:  Hypertens Res        ISSN: 0916-9636            Impact factor:   3.872


  8 in total

1.  Kidney function predicts the risk of asymptomatic peripheral arterial disease in a Chinese community-based population.

Authors:  Zhongli Wu; Xingang Wang; Jia Jia; Yuxi Li; Yimeng Jiang; Jianping Li; Yong Huo; Fangfang Fan; Yan Zhang
Journal:  Int Urol Nephrol       Date:  2020-02-01       Impact factor: 2.370

2.  An evaluation of ankle-brachial blood pressure index in adult Nigerians with sickle cell anaemia.

Authors:  N I Oguanobi; B J Onwubere; O G Ibegbulam; S O Ike; E C Ejim; O Agwu
Journal:  Cardiovasc J Afr       Date:  2012-02       Impact factor: 1.167

3.  An exploration of the relationship between foot skin temperature and blood flow in type 2 diabetes mellitus patients: a cross-sectional study.

Authors:  Uraiwan Chatchawan; Patsakorn Narkto; Tanchanok Damri; Junichiro Yamauchi
Journal:  J Phys Ther Sci       Date:  2018-11-06

4.  Visceral adiposity index and sex differences in relation to peripheral artery disease in normal-weight adults with hypertension.

Authors:  Yumeng Shi; Chao Yu; Lihua Hu; Minghui Li; Wei Zhou; Tao Wang; Lingjuan Zhu; Huihui Bao; Ping Li; Xiaoshu Cheng
Journal:  Biol Sex Differ       Date:  2022-05-12       Impact factor: 8.811

5.  Automated ankle-brachial pressure index measurement by clinical staff for peripheral arterial disease diagnosis in nondiabetic and diabetic patients.

Authors:  Cécile Clairotte; Sylvie Retout; Louis Potier; Ronan Roussel; Brigitte Escoubet
Journal:  Diabetes Care       Date:  2009-04-14       Impact factor: 19.112

6.  The Association of Four-Limb Blood Pressure with History of Stroke in Chinese Adults: A Cross-Sectional Study.

Authors:  Hong Guo; Fengyu Sun; Lihang Dong; Huiying Chang; Xingbo Gu; Haiyu Zhang; Lijiang Sheng; Ye Tian
Journal:  PLoS One       Date:  2015-10-09       Impact factor: 3.240

7.  Small infrarenal aortic diameter associated with lower-extremity peripheral artery disease in Chinese hypertensive adults.

Authors:  Jie Liu; Xin Jia; Senhao Jia; Xianhui Qin; Tao Zhang; Lishun Liu; Haibo Li; Dan Rong; Ziyi Zhou; Yuxiang Song; Shangwei Zuo; Chen Duan; Zhongyin Wu; Ren Wei; Yangyang Ge; Xian Wang; Wei Kong; Xiping Xu; Raouf A Khalil; Yong Huo; Wei Guo
Journal:  Sci Rep       Date:  2017-11-06       Impact factor: 4.379

8.  The reliability of the ankle brachial index: a systematic review.

Authors:  Sarah Casey; Sean Lanting; Christopher Oldmeadow; Vivienne Chuter
Journal:  J Foot Ankle Res       Date:  2019-08-02       Impact factor: 2.303

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.