Literature DB >> 17664639

Protective ventilation using electrical impedance tomography.

H Luepschen1, T Meier, M Grossherr, T Leibecke, J Karsten, S Leonhardt.   

Abstract

Dynamic thoracic EIT is capable of detecting changes of the ventilation distribution in the lung. Nevertheless, it has yet to become an established clinical tool. Therefore, it is necessary to consider application scenarios wherein fast and distinct changes of the tissue conductivities are to be found and also have a clear diagnostic significance. One such a scenario is the artificial ventilation of patients suffering from the acute respiratory distress syndrome (ARDS). New protective ventilation strategies involving recruitment manoeuvres are associated with noticeable shifts of body fluids and regional ventilation, which can quite easily be detected by EIT. The bedside assessment of these recruitment manoeuvres will help the attending physician to optimize treatment. Hence, we performed an animal study of lavage-induced lung failure and investigated if EIT is capable of qualitatively as well as quantitatively monitoring lung recruitment during a stepwise PEEP trial. Additionally, we integrated EIT into a fuzzy controller-based ventilation system which allows one to perform automated recruitment manoeuvres (open lung concept) based on online PaO2 measurements. We found that EIT is a useful tool to titrate the proper PEEP level after fully recruiting the lung. Furthermore, EIT seems to be able to determine the status of recruitment when combining it with other physiological parameters. These results suggest that EIT may play an important role in the individualization of protective ventilation strategies.

Entities:  

Mesh:

Year:  2007        PMID: 17664639     DOI: 10.1088/0967-3334/28/7/S18

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  19 in total

Review 1.  Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?

Authors:  Steffen Leonhardt; Burkhard Lachmann
Journal:  Intensive Care Med       Date:  2012-09-20       Impact factor: 17.440

Review 2.  Electrical impedance tomography.

Authors:  Beatriz Lobo; Cecilia Hermosa; Ana Abella; Federico Gordo
Journal:  Ann Transl Med       Date:  2018-01

3.  PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography.

Authors:  Zhanqi Zhao; Daniel Steinmann; Inéz Frerichs; Josef Guttmann; Knut Möller
Journal:  Crit Care       Date:  2010-01-30       Impact factor: 9.097

4.  Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial.

Authors:  Ido G Bikker; Carsten Preis; Mahamud Egal; Jan Bakker; Diederik Gommers
Journal:  Crit Care       Date:  2011-08-11       Impact factor: 9.097

Review 5.  Role of electrical impedance tomography in clinical practice in pediatric respiratory medicine.

Authors:  Wojciech Durlak; Przemko Kwinta
Journal:  ISRN Pediatr       Date:  2013-12-25

6.  Electrical Impedance Tomography-guided PEEP Titration in Patients Undergoing Laparoscopic Abdominal Surgery.

Authors:  Xingying He; Jingjing Jiang; Yuli Liu; Haitao Xu; Shuangqiong Zhou; Shibo Yang; Xueyin Shi; Hongbin Yuan
Journal:  Medicine (Baltimore)       Date:  2016-04       Impact factor: 1.889

7.  Impact of four different recumbencies on the distribution of ventilation in conscious or anaesthetized spontaneously breathing beagle dogs: An electrical impedance tomography study.

Authors:  Tamas D Ambrisko; Johannes P Schramel; Ulrike Auer; Yves P S Moens
Journal:  PLoS One       Date:  2017-09-18       Impact factor: 3.240

8.  Electrical impedance tomography applied to assess matching of pulmonary ventilation and perfusion in a porcine experimental model.

Authors:  Anneli Fagerberg; Ola Stenqvist; Anders Aneman
Journal:  Crit Care       Date:  2009-03-05       Impact factor: 9.097

9.  Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels.

Authors:  Ido G Bikker; Steffen Leonhardt; Jan Bakker; Diederik Gommers
Journal:  Intensive Care Med       Date:  2009-06-10       Impact factor: 17.440

Review 10.  Electrical impedance tomography in acute respiratory distress syndrome.

Authors:  M Consuelo Bachmann; Caio Morais; Guillermo Bugedo; Alejandro Bruhn; Arturo Morales; João B Borges; Eduardo Costa; Jaime Retamal
Journal:  Crit Care       Date:  2018-10-25       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.