Literature DB >> 17664187

Stenting of the arterial duct in newborns with duct-dependent pulmonary circulation.

G Santoro1, G Gaio, M T Palladino, C Iacono, M Carrozza, R Esposito, M G Russo, G Caianiello, R Calabrò.   

Abstract

OBJECTIVE: To evaluate the feasibility and results of stenting of the arterial duct in newborns with duct-dependent pulmonary circulation using low-profile, high-flexibility premounted coronary stents.
DESIGN: Prospective interventional and clinical follow-up study.
SETTING: Tertiary referral centre. PATIENT POPULATION: Between April 2003 and December 2006, 26 neonates (mean (SD) age 15.2 (19.9) days, mean (SD) weight 3.3 (0.8) kg) underwent attempts at stenting of the arterial duct. MAIN OUTCOME MEASURES: Procedural success and complication rates. Early and mid-term follow-up results.
RESULTS: The procedure was successfully completed in 24/26 (92.3%) cases. Minor complications occurred in 2/26 (7.7%) cases. No mortality occurred. After stenting, the ductal diameter increased from 1.2 (1.0) mm to 3.1 (0.4) mm (p<0.001) and the percutaneous O(2) saturation increased from 70 (14)% to 86 (10)% (p<0.001), respectively. Over a mid-term follow-up, 2/24 patients (8.3%) needed a systemic-to-pulmonary artery shunt because of inadequate ductal flow and 4/24 patients (16.7%) underwent stent redilatation after 6.0 (4.4) months, but before corrective surgery. Cardiac catheterisation before corrective surgery in 9 patients showed an increase of the Nakata index from 112 (49) mm/mm(2) to 226 (108) mm/mm(2) (p<0.001), without any left-to-right imbalance of the pulmonary artery size. In the subset of 11 patients who improved without needing an additional source of pulmonary blood supply, the stented arterial duct closed uneventfully in 45.5% of cases after 4.0 (2.2) months.
CONCLUSIONS: Stenting of the arterial duct is a feasible, safe and effective palliation in newborns with duct-dependent pulmonary circulation, supporting the spontaneous improvement process or promoting significant and balanced pulmonary artery growth for subsequent corrective surgery.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17664187     DOI: 10.1136/hrt.2007.123000

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  8 in total

1.  Stent implantation of patent ductus arteriosus in a newborn baby.

Authors:  Prabhat Kumar; R Datta; R Nair; G Sridhar
Journal:  Med J Armed Forces India       Date:  2011-07-21

2.  Preprocedural three-dimensional planning aids in transcatheter ductal stent placement: A single-center experience.

Authors:  Reid C Chamberlain; Jordan E Ezekian; Gregory M Sturgeon; Piers C A Barker; Kevin D Hill; Gregory A Fleming
Journal:  Catheter Cardiovasc Interv       Date:  2019-12-18       Impact factor: 2.692

3.  Patent ductus arteriosus stenting in complex congenital heart disease: early and midterm results for a single-center experience at children hospital, Mansoura, Egypt.

Authors:  Mohamed Matter; Hala Almarsafawey; Mona Hafez; Gehan Attia; Mohamed-Magdy Abuelkheir
Journal:  Pediatr Cardiol       Date:  2012-12-13       Impact factor: 1.655

4.  Differences in Cost of Care by Palliation Strategy for Infants With Ductal-Dependent Pulmonary Blood Flow.

Authors:  Bryan H Goldstein; Michael L O'Byrne; Christopher J Petit; Athar M Qureshi; Dingwei Dai; Heather M Griffis; Ashton France; Michael S Kelleman; Courtney E McCracken; Christopher E Mascio; Subi Shashidharan; R Allen Ligon; Wendy Whiteside; W Jack Wallen; Hitesh Agrawal; Varun Aggarwal; Andrew C Glatz
Journal:  Circ Cardiovasc Interv       Date:  2019-04       Impact factor: 6.546

5.  Feasibility, safety, and efficacy of iron bioresorbable scaffold in neonates with duct-dependent pulmonary circulation.

Authors:  Marhisham Che Mood; Khalil Ahmad Niazy; Mazeni Alwi; Hasri Samion; Koh Ghee Tiong; Sivakumar Sivalingam; Deyuan Zhang
Journal:  Ann Pediatr Cardiol       Date:  2022-08-19

Review 6.  Impact of stent of ductus arteriosus and modified Blalock-Taussig shunt on pulmonary arteries growth and second-stage surgery in infants with ductus-dependent pulmonary circulation.

Authors:  Bana Agha Nasser; Mesned Abdulrahman; Abdullah A L Qwaee; Ali Alakfash; Tageldein Mohamad; Mohamed S Kabbani
Journal:  J Saudi Heart Assoc       Date:  2020-04-17

7.  Neonatal patent ductus arteriosus recanalization and stenting in critical Ebstein's anomaly.

Authors:  G Santoro; M T Palladino; M G Russo; R Calabrò
Journal:  Pediatr Cardiol       Date:  2007-09-15       Impact factor: 1.655

8.  Use of the ductal curvature index to assess the risk of ductal stenting in patients with duct-dependent pulmonary circulation.

Authors:  Nathalie Mini; Martin B E Schneider; Peter A Zartner
Journal:  Transl Pediatr       Date:  2021-05
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.