Literature DB >> 17664099

Endovascular abdominal aortic aneurysm repair in patients with common iliac artery aneurysms--Initial experience with the Zenith bifurcated iliac side branch device.

Ferdinand Serracino-Inglott1, Alan E Bray, Paul Myers.   

Abstract

OBJECTIVE: To present our initial experience with the Zenith bifurcated iliac side branch device that preserves internal iliac artery flow whilst excluding aorto-iliac aneurysms.
METHODS: Between November 2005 and October 2006, data was prospectively collected on 8 patients in whom this device was used; 2 aorto-bi-iliac aneurysms, 3 aorto-uni-iliac aneurysms, 1 solitary common iliac aneurysm, 1 distal type 1 endoleak, and 1 internal iliac aneurysm.
RESULTS: No mortality or major complications resulted from use of this device. The median fluoroscopy time was 53 minutes (range 38 to 105) and a median of 102 g of iodine (range 84 to 130) as contrast were used. One patient required a blood transfusion and only one of the eight side branches occluded. There has been no endoleak related to the device in the median follow-up period of 6 months (1 to 14 months).
CONCLUSION: This device provides an alternative for the management of patients with aorto-iliac aneurysms that is safe and less complex than, previously described, hybrid procedures that preserve internal iliac flow.

Entities:  

Mesh:

Year:  2007        PMID: 17664099     DOI: 10.1016/j.jvs.2007.03.040

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  5 in total

1.  Endovascular repair of bilateral iliac artery aneurysm with branched iliac stents: case report and review of the current literature.

Authors:  Ji Hoon You; Hoon-Ki Park; Chang-Bum Park
Journal:  J Korean Surg Soc       Date:  2013-08-26

2.  Early outcomes of iliac branch grafts in the endovascular repair of abdominal aortic aneurysms with concomitant bilateral common iliac artery aneurysms at a Japanese institution.

Authors:  Naoki Unno; Naoto Yamamoto; Kazunori Inuzuka; Yuuki Mano; Masaki Sano; Takaaki Saito; Ryota Sugisawa; Kazuto Katahashi; Hiroyuki Konno
Journal:  Surg Today       Date:  2014-05-18       Impact factor: 2.549

3.  Multicentre experience with an iliac fenestrated device.

Authors:  Fadi Taher; Stephan Langer; Juergen Falkensammer; Markus Plimon; Miriam Kliewer; Corinna Walter; Afshin Assadian; Alexander Stehr
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-08-18

4.  Three-vessel fenestrated and bilateral iliac branched graft repair of a juxtarenal aortic aneurysm with bilateral common iliac aneurysms.

Authors:  Emily B Worrall; Niten Singh; Benjamin W Starnes
Journal:  J Vasc Surg Cases Innov Tech       Date:  2018-04-30

5.  A Multicenter Assessment of Anatomic Suitability for Iliac Branched Devices in Eastern Asian Patients With Unilateral and Bilateral Aortoiliac Aneurysms.

Authors:  Zheyun Li; Min Zhou; Guili Wang; Tong Yuan; Enci Wang; Yufei Zhao; Xiaolong Shu; Yuchong Zhang; Peng Lin; Weiguo Fu; Lixin Wang
Journal:  Front Cardiovasc Med       Date:  2022-01-03
  5 in total