IFCC guideline for sampling, measuring and reporting ionized magnesium in plasma.

Mohammed C Ben Rayana1, Robert W Burnett, Arthur K Covington, Paul D'Orazio, Niels Fogh-Andersen, Ellis Jacobs, Wolf R Külpmann, Katsuhiko Kuwa, Lasse Larsson, Andrzej Lewenstam, Anton H J Maas, Gerhard Mager, Jerzy W Naskalski, Anthony O Okorodudu, Christoph Ritter, Andrew St John.   

Abstract

Analyzers with ion-selective electrodes (ISEs) for ionized magnesium (iMg) should yield comparable and unbiased results for iMg. This IFCC guideline on sampling, measuring and reporting iMg in plasma provides a prerequisite to achieve this goal [in this document, "plasma" refers to circulating plasma and the forms in which it is sampled, namely the plasma phase of anticoagulated whole blood (or "blood"), plasma separated from blood cells, or serum]. The guideline recommends measuring and reporting ionized magnesium as a substance concentration relative to the substance concentration of magnesium in primary aqueous calibrants with magnesium, sodium, and calcium chloride of physiological ionic strength. The recommended name is "the concentration of ionized magnesium in plasma". Based on this guideline, results will be approximately 3% higher than the true substance concentration and 4% lower than the true molality in plasma. Calcium ions interfere with all current magnesium ion-selective electrodes (Mg-ISEs), and thus it is necessary to determine both ions simultaneously in each sample and correct the result for Ca2+ interference. Binding of Mg in plasma is pH-dependent. Therefore, pH should be measured simultaneously with iMg to allow adjustment of the result to pH 7.4. The concentration of iMg in plasma may be physiologically and clinically more relevant than the concentration of total magnesium. Furthermore, blood-gas analyzers or instruments for point-of-care testing are able to measure plasma iMg using whole blood (with intact blood cells) as the sample, minimizing turn-around time compared to serum and plasma, which require removal of blood cells.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 17663628     DOI: 10.1515/CCLM.2008.001

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  3 in total

1.  Hemoglobin oxygen affinity in patients with cystic fibrosis.

Authors:  Dieter Böning; Angela Littschwager; Matthias Hütler; Ralph Beneke; Doris Staab
Journal:  PLoS One       Date:  2014-06-11       Impact factor: 3.240

2.  The effects of different syringe volume, needle size and sample volume on blood gas analysis in syringes washed with heparin.

Authors:  Tuncay Küme; Ali Riza Sişman; Ahmet Solak; Birsen Tuğlu; Burcu Cinkooğlu; Canan Coker
Journal:  Biochem Med (Zagreb)       Date:  2012       Impact factor: 2.313

Review 3.  Magnesium: Biochemistry, Nutrition, Detection, and Social Impact of Diseases Linked to Its Deficiency.

Authors:  Diana Fiorentini; Concettina Cappadone; Giovanna Farruggia; Cecilia Prata
Journal:  Nutrients       Date:  2021-03-30       Impact factor: 5.717

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.