Literature DB >> 17661929

Nasal hyperreactivity in allergic and non-allergic rhinitis: a potential risk factor for non-specific building-related illness.

D Shusterman1, M A Murphy.   

Abstract

UNLABELLED: Self-reported non-allergic nasal symptom triggers in non-allergic ('vasomotor') rhinitis overlap with commonly identified environmental exposures in non-specific building-related illness. These include extremes of temperature and humidity, cleaning products, fragrances, and tobacco smoke. Some individuals with allergic rhinitis also report non-allergic triggers. We wished to explore the phenotypic overlap between allergic and non-allergic rhinitis by ascertaining self-reported non-allergic nasal symptom triggers among allergic rhinitics. Sixty subjects without work-related respiratory exposures or symptoms, aged 19-68 years, stratified by age, gender and (skin test-proven) allergic rhinitis status, were queried with regard to self-reported non-allergic nasal symptom triggers (aggregate score 0-8). In this sample, the number of self-reported non-allergic triggers was bimodal, with peaks at 1 and 5. Forty-two percent of seasonal allergic rhinitic subjects reported more than three non-allergic triggers, compared with only 3% of non-allergic non-rhinitics (P < 0.01). Subjects over 35 years were more likely to report one or more non-allergic triggers, particularly tobacco smoke (P < 0.05). Allergic rhinitics reported more non-allergic symptom triggers than did non-allergic, non-rhinitics. As indexed by self-reported reactivity to non-specific physical and chemical triggers, both non-allergic rhinitics and a subset of allergic rhinitics may constitute susceptible populations for non-specific building-related illness. PRACTICAL IMPLICATIONS: Judging by self-report, a substantial subset of individuals with allergic rhinitis--along with all individuals with nonallergic rhinitis (by definition)--are hyperreactive to non-allergic triggers. There is overlap between these triggers (elicited in the process of obtaining a clinical diagnosis) and environmental characteristics associated with ''problem buildings.'' Since individuals with self-identified rhinitis report an excess of symptoms in most epidemiologic studies of problem buildings (even in the absence of unusual aeroallergen levels), rhintics may be acting as a ''sentinel'' subgroup when indoor air quality is suboptimal. Together, non-allergic rhinitics plus allergic rhinitics with prominent non-allergic triggers, are thought to constitute approximately one-sixth of the US population.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17661929     DOI: 10.1111/j.1600-0668.2007.00482.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  13 in total

Review 1.  Occupational irritant and allergic rhinitis.

Authors:  Dennis Shusterman
Journal:  Curr Allergy Asthma Rep       Date:  2014-04       Impact factor: 4.806

2.  Computational fluid dynamics and trigeminal sensory examinations of empty nose syndrome patients.

Authors:  Chengyu Li; Alexander A Farag; James Leach; Bhakthi Deshpande; Adam Jacobowitz; Kanghyun Kim; Bradley A Otto; Kai Zhao
Journal:  Laryngoscope       Date:  2017-03-09       Impact factor: 3.325

3.  Association of Allergic Rhinitis With Change in Nasal Congestion in New Continuous Positive Airway Pressure Users.

Authors:  Jonathan R Skirko; Kathryn T James; Dennis J Shusterman; Edward M Weaver
Journal:  JAMA Otolaryngol Head Neck Surg       Date:  2020-06-01       Impact factor: 6.223

4.  Investigation of the abnormal nasal aerodynamics and trigeminal functions among empty nose syndrome patients.

Authors:  Chengyu Li; Alexander A Farag; Guillermo Maza; Sam McGhee; Michael A Ciccone; Bhakthi Deshpande; Edmund A Pribitkin; Bradley A Otto; Kai Zhao
Journal:  Int Forum Allergy Rhinol       Date:  2017-11-22       Impact factor: 3.858

5.  The placebo effect: plugging the nostrils of unmet needs.

Authors:  James N Baraniuk
Journal:  Curr Allergy Asthma Rep       Date:  2009-03       Impact factor: 4.806

6.  Chemosensory loss: functional consequences of the world trade center disaster.

Authors:  Pamela H Dalton; Richard E Opiekun; Michele Gould; Ryan McDermott; Tamika Wilson; Christopher Maute; Mehmet H Ozdener; Kai Zhao; Edward Emmett; Peter S J Lees; Robin Herbert; Jacqueline Moline
Journal:  Environ Health Perspect       Date:  2010-05-13       Impact factor: 9.031

7.  Regional peak mucosal cooling predicts the perception of nasal patency.

Authors:  Kai Zhao; Jianbo Jiang; Kara Blacker; Brian Lyman; Pamela Dalton; Beverly J Cowart; Edmund A Pribitkin
Journal:  Laryngoscope       Date:  2013-06-28       Impact factor: 3.325

8.  Relationship between environment factors and the number of outpatient visits at a clinic for nonallergic rhinitis in Japan, extracted from electronic medical records.

Authors:  Takayuki Hoshino; Ayami Hoshino; Junya Nishino
Journal:  Eur J Med Res       Date:  2015-07-08       Impact factor: 2.175

9.  Pathogenic mechanisms of idiopathic nonallergic rhinitis.

Authors:  James N Baraniuk
Journal:  World Allergy Organ J       Date:  2009-06-15       Impact factor: 4.084

10.  Rhinitis symptoms and asthma among parents of preschool children in relation to the home environment in Chongqing, China.

Authors:  Juan Wang; Baizhan Li; Wei Yu; Qin Yang; Han Wang; Duchai Huang; Jan Sundell; Dan Norbäck
Journal:  PLoS One       Date:  2014-04-14       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.