Milk flow rates can be used to identify and investigate milk ejection in women expressing breast milk using an electric breast pump.

Donna T Ramsay1, Leon R Mitoulas, Jacqueline C Kent, Mark D Cregan, Dorota A Doherty, Michael Larsson, Peter E Hartmann.   

Abstract

Currently there is no simple method available to assess milk ejection and breast milk flow in lactating women in both the clinical and research setting. The authors hypothesize that changes in milk flow rate are associated with milk ejection and therefore may provide a method suitable for the assessment of milk ejection and removal. Mothers (n = 23) expressed milk from one breast for a 15-minute period using both weak and strong vacuums on two to four separate occasions using an experimental electric breast pump (Medela AG, Baar, Switzerland). Breast milk flow rates were recorded at 5-second intervals by connecting a tube from the breast shield to a bottle placed on a balance that was connected to a computer. Milk ejection was determined by an acute increase in milk duct diameter in the contralateral breast using ultrasound (Acuson XP10, Siemens, Mountain View, CA), and the change in duct diameter was compared with milk flow rates. Milk flow rates ranged from 0 to 4.6 g per 5-second period. Increases in flow rates were positively associated with increases in duct diameter (p < 0.05). Furthermore, within each milk ejection, higher maximum duct diameters were positively related to greater volumes expressed per 5-second periods (p < 0.001). Time to the first milk ejection and number of milk ejections were the same when determined by ultrasound or flow rates. This direct relationship between increases in duct diameter and acute increases in milk flow rates suggests that changes in flow rates can be used to identify milk ejection in the absence of ultrasound data.

Entities:  

Mesh:

Year:  2006        PMID: 17661556     DOI: 10.1089/bfm.2006.1.14

Source DB:  PubMed          Journal:  Breastfeed Med        ISSN: 1556-8253            Impact factor:   1.817


  11 in total

1.  Mining for liquid gold: midwifery language and practices associated with early breastfeeding support.

Authors:  Elaine Burns; Jenny Fenwick; Athena Sheehan; Virginia Schmied
Journal:  Matern Child Nutr       Date:  2012-03-09       Impact factor: 3.092

2.  Detection of Milk Ejection Using Bioimpedance Spectroscopy in Lactating Women during Milk Expression Using an Electric Breast Pump.

Authors:  Hazel Gardner; Ching Tat Lai; Leigh Ward; Donna Geddes
Journal:  J Mammary Gland Biol Neoplasia       Date:  2019-02-13       Impact factor: 2.673

Review 3.  Which breast pump for which mother: an evidence-based approach to individualizing breast pump technology.

Authors:  P P Meier; A L Patel; R Hoban; J L Engstrom
Journal:  J Perinatol       Date:  2016-02-25       Impact factor: 2.521

4.  Characterisation of sucking dynamics of breastfeeding preterm infants: a cross sectional study.

Authors:  Donna T Geddes; Kok Chooi; Kathryn Nancarrow; Anna R Hepworth; Hazel Gardner; Karen Simmer
Journal:  BMC Pregnancy Childbirth       Date:  2017-11-17       Impact factor: 3.007

5.  Comparison of maternal milk ejection characteristics during pumping using infant-derived and 2-phase vacuum patterns.

Authors:  Hazel Gardner; Jacqueline C Kent; Ching Tat Lai; Donna T Geddes
Journal:  Int Breastfeed J       Date:  2019-11-06       Impact factor: 3.461

6.  Using milk flow rate to investigate milk ejection in the left and right breasts during simultaneous breast expression in women.

Authors:  Danielle K Prime; Donna T Geddes; Diane L Spatz; Marc Robert; Naomi J Trengove; Peter E Hartmann
Journal:  Int Breastfeed J       Date:  2009-10-26       Impact factor: 3.461

7.  The use of ultrasound to identify milk ejection in women - tips and pitfalls.

Authors:  Donna T Geddes
Journal:  Int Breastfeed J       Date:  2009-06-01       Impact factor: 3.461

8.  Ultrasound imaging of the lactating breast: methodology and application.

Authors:  Donna T Geddes
Journal:  Int Breastfeed J       Date:  2009-04-29       Impact factor: 3.461

9.  Milk ejection patterns: an intra- individual comparison of breastfeeding and pumping.

Authors:  Hazel Gardner; Jacqueline C Kent; Ching Tat Lai; Leon R Mitoulas; Mark D Cregan; Peter E Hartmann; Donna T Geddes
Journal:  BMC Pregnancy Childbirth       Date:  2015-07-30       Impact factor: 3.007

10.  Breast shield design impacts milk removal dynamics during pumping: A randomized controlled non-inferiority trial.

Authors:  Vanessa S Sakalidis; Lennart Ivarsson; Alan G Haynes; Linda Jäger; Nania G Schärer-Hernández; Leon R Mitoulas; Danielle K Prime
Journal:  Acta Obstet Gynecol Scand       Date:  2020-06-05       Impact factor: 4.544