BACKGROUND: Current practice guidelines for managing patients with chronic myelogenous leukemia (CML) call for monitoring BCR-ABL transcript concentrations with a quantitative reverse transcription-PCR (qRT-PCR) assay. Because the available laboratory-developed assays lack consensus on the appropriate design, reporting of results, and reference intervals, we developed and evaluated an integrated BCR-ABL assay that yields standardized results for any laboratory and can be performed by technicians with no specialized training. METHODS: We used the Cepheid Xpert BCR-ABL Monitor assay to measure both BCR-ABL and ABL (endogenous control) transcripts in blood samples from CML patients and healthy individuals. The assay involves 8 manual pipetting steps, fully automated nucleic acid purification, a nested qRT-PCR step, and data analysis. RESULTS: The BCR-ABL assay requires approximately 2 h 20 min and covers a 5-log concentration range with a lower detection limit for the BCR-ABL:ABL ratio of approximately 0.005%. Assay results were negative for 100% of the 56 known CML-negative samples (12 patients with other hematologic disorders and 44 healthy blood donors). Testing of CML-positive patients undergoing disease monitoring showed 85% agreement with negative results (17 of 20) and 100% agreement with positive results (26 of 26). An imprecision/portability study revealed no differences in performance between sites, days, instruments, and operators. CONCLUSIONS: The Xpert BCR-ABL Monitor assay provides a robust and reproducible alternative to laboratory-developed assays. Its ease of use may allow more laboratories to offer BCR-ABL testing for patients, and the short assay time enables same-day results for treating physicians.
BACKGROUND: Current practice guidelines for managing patients with chronic myelogenous leukemia (CML) call for monitoring BCR-ABL transcript concentrations with a quantitative reverse transcription-PCR (qRT-PCR) assay. Because the available laboratory-developed assays lack consensus on the appropriate design, reporting of results, and reference intervals, we developed and evaluated an integrated BCR-ABL assay that yields standardized results for any laboratory and can be performed by technicians with no specialized training. METHODS: We used the Cepheid Xpert BCR-ABL Monitor assay to measure both BCR-ABL and ABL (endogenous control) transcripts in blood samples from CMLpatients and healthy individuals. The assay involves 8 manual pipetting steps, fully automated nucleic acid purification, a nested qRT-PCR step, and data analysis. RESULTS: The BCR-ABL assay requires approximately 2 h 20 min and covers a 5-log concentration range with a lower detection limit for the BCR-ABL:ABL ratio of approximately 0.005%. Assay results were negative for 100% of the 56 known CML-negative samples (12 patients with other hematologic disorders and 44 healthy blood donors). Testing of CML-positive patients undergoing disease monitoring showed 85% agreement with negative results (17 of 20) and 100% agreement with positive results (26 of 26). An imprecision/portability study revealed no differences in performance between sites, days, instruments, and operators. CONCLUSIONS: The Xpert BCR-ABL Monitor assay provides a robust and reproducible alternative to laboratory-developed assays. Its ease of use may allow more laboratories to offer BCR-ABL testing for patients, and the short assay time enables same-day results for treating physicians.
Authors: Jerald P Radich; Edward Briercheck; Daniel T Chiu; Manoj P Menon; Olga Sala Torra; Cecilia C S Yeung; Edus H Warren Journal: Annu Rev Pathol Date: 2022-01-24 Impact factor: 32.350
Authors: Tariq I Mughal; Jerald P Radich; Michael W Deininger; Jane F Apperley; Timothy P Hughes; Christine J Harrison; Carlo Gambacorti-Passerini; Giuseppe Saglio; Jorge Cortes; George Q Daley Journal: Haematologica Date: 2016-05 Impact factor: 9.941
Authors: Angelo M Carella; Susan Branford; Michael Deininger; Francois X Mahon; Giuseppe Saglio; Anna Eiring; Jamshid Khorashad; Thomas O'Hare; John M Goldman Journal: Haematologica Date: 2013-08 Impact factor: 9.941
Authors: Anoop Enjeti; Neil Granter; Asma Ashraf; Linda Fletcher; Susan Branford; Philip Rowlings; Susan Dooley Journal: Pathology Date: 2015-10 Impact factor: 5.306