Literature DB >> 17659446

New technology for cellular piercing: rotationally oscillating mu-injector, description and validation tests.

Ali Fuat Ergenc1, Nejat Olgac.   

Abstract

ICSI (intracytoplasmic sperm injection) procedure is one of the most commonly used cellular-injection processes. In ICSI a drawn glass pipette is pushed against the biological cell and a series of force impulses are exerted on it axially to achieve the piercing through the zona and the membrane in sequence for the ensuing injection. In most advanced applications a piezo actuator creates this impulsive forcing. This procedure presently requires a very small mercury column inside the glass pipette which is found to be helpful especially for minimizing the transverse oscillations. Despite the toxic mercury, the procedure is commonly utilized in many laboratories. Earlier investigations point out that considerable lateral tip oscillations of the injection pipette remain as the piezo-electric pulses are introduced. Such oscillations damage the cell membrane and impart adverse effects on the success rate of the injection. In this study, we introduce a novel microinjection procedure, which will remedy the shortfalls of the present technology. The highlight of this procedure is the introduction of rotational oscillations to the pipette during the drilling. These oscillations of small amplitudes (few degrees) and high enough frequencies (100 Hz and higher) are shown to create very effective piercing. The so-called Ros-Drill is a mercury-free and minimally invasive device of which the prototypes are designed and built including the relevant peripheral control hardware and software. Preliminary experimental results are presented on mouse oocytes and they are very encouraging. In the early trials on mouse oocytes, several blastocyst stage developments are reported using new drilling device. We also explain in this text the implementation protocols developed for the new technology.

Entities:  

Mesh:

Year:  2007        PMID: 17659446     DOI: 10.1007/s10544-007-9102-2

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  2 in total

1.  Rotationally oscillating drill (Ros-Drill) for mouse ICSI without using mercury.

Authors:  Ali Fuat Ergenc; Ming-Wen Li; Mehmet Toner; John D Biggers; K C Kent Lloyd; Nejat Olgac
Journal:  Mol Reprod Dev       Date:  2008-12       Impact factor: 2.609

2.  An Adaptive Control Method for Ros-Drill Cellular Microinjector with Low-Resolution Encoder.

Authors:  Zhenyu Zhang; Nejat Olgac
Journal:  J Med Eng       Date:  2013-03-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.