Accuracy of real-time 3D echocardiography in the evaluation of functional anatomy of mitral regurgitation.

Eustachio Agricola1, Michele Oppizzi, Matteo Pisani, Francesco Maisano, Alberto Margonato.   

Abstract

OBJECTIVE: To evaluate the feasibility of mitral valve (MV) reconstruction protocol by real-time 3D echocardiography (RT3DE) in the assessment mitral regurgitant (MR) lesions, and to determine the accuracy of RT3DE compared with transthoracic (TTE) and transesophageal (TEE) echocardiographies using surgical findings as gold standard. PATIENTS AND METHODS: Sixty-three consecutive patients (mean age 61.7+/-12.5 years, 35 men and 28 women) with severe organic MR were enrolled. Data were acquired in zoom and in full-volume modes from apical and/or parasternal windows. A volume rendered en-face view of MV and five serial longitudinal cut planes were reconstructed to visualize all segments of both leaflets.
RESULTS: The feasibility of RT3D reconstruction was 94%. Compared with surgical diagnosis, the accuracy of RT3D was 91% for aetiology, 92% for mechanisms, 94% for prolapse, 88% for flail and 94% for defect location. Diagnostic accuracy was significant higher for RT3D than TTE for all end points except for flail lesion and similar to TEE but inferior to this for flail lesion. The accuracy, sensitivity and specificity were higher in patients with good-excellent than those with poor image quality regarding aetiology, mechanisms and defect location (all p=0.0001).
CONCLUSIONS: RT3D imaging of MV is feasible and accurate in defining aetiology, mechanism and defect location in patients with MR and has incremental diagnostic value if TTE is inconclusive and similar diagnostic value of TEE except for flail lesion. RT3D, at least in patients with good acoustic window, may obviate the need for subsequent TEE and/or can be considered a complementary technique to study MV in patients with MR.

Entities:  

Mesh:

Year:  2007        PMID: 17658629     DOI: 10.1016/j.ijcard.2007.05.010

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  11 in total

1.  Discrimination between fibroelastic deficiency and Barlow disease using parameters of mitral annulus derived from real-time three-dimensional echocardiography.

Authors:  Sylva Kovalova; Josef Necas; Ondrej Mikula
Journal:  J Echocardiogr       Date:  2013-01-26

2.  Feasibility of measurements of valve dimensions in en-face-3D transesophageal echocardiography.

Authors:  Sarah Eibel; Edwin Turton; Chirojit Mukherjee; Carmine Bevilacqua; Joerg Ender
Journal:  Int J Cardiovasc Imaging       Date:  2017-05-09       Impact factor: 2.357

Review 3.  Role of Echocardiography in the Evaluation of Left Ventricular Assist Devices: the Importance of Emerging Technologies.

Authors:  Luca Longobardo; Christopher Kramer; Scipione Carerj; Concetta Zito; Renuka Jain; Valentin Suma; Vinay Thohan; Nasir Sulemanjee; Frank X Downey; Bijoy K Khandheria
Journal:  Curr Cardiol Rep       Date:  2016-07       Impact factor: 2.931

Review 4.  Degenerative Mitral Regurgitation: Assessment, Physical Examination, and Imaging.

Authors:  Nina C Wunderlich; Roy Beigel; Florian Rader; Jennifer Franke; Robert J Siegel
Journal:  Curr Cardiol Rep       Date:  2019-07-22       Impact factor: 2.931

5.  Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography.

Authors:  J Ender; S Eibel; C Mukherjee; D Mathioudakis; M A Borger; S Jacobs; F W Mohr; V Falk
Journal:  Eur J Echocardiogr       Date:  2011-05-04

6.  Real-time three dimensional transesophageal echocardiography: technical aspects and clinical applications.

Authors:  Eustachio Agricola; Luigi Badano; Donato Mele; Maurizio Galderisi; Massimo Slavich; Susanna Sciomer; Stefano Nistri; Piercarlo Ballo; Antonello D'Andrea; Sergio Mondillo
Journal:  Heart Int       Date:  2010-06-23

7.  Real-time three-dimensional transthoracic echocardiography in daily practice: initial experience.

Authors:  Ashraf M Anwar; Youssef F M Nosir; Siti Khairani Zainal-Abidin; Aref Ajam; Hassan Chamsi-Pasha
Journal:  Cardiovasc Ultrasound       Date:  2012-03-26       Impact factor: 2.062

Review 8.  Role of modern 3D echocardiography in valvular heart disease.

Authors:  Takahiro Shiota
Journal:  Korean J Intern Med       Date:  2014-10-31       Impact factor: 2.884

9.  Transthoracic two-dimensional xPlane and three-dimensional echocardiographic analysis of the site of mitral valve prolapse.

Authors:  Jackie S McGhie; Lotte de Groot-de Laat; Ben Ren; Wim Vletter; René Frowijn; Frans Oei; Marcel L Geleijnse
Journal:  Int J Cardiovasc Imaging       Date:  2015-08-15       Impact factor: 2.357

Review 10.  Imaging modalities in valvular heart disease.

Authors:  Francisco Aguilar; H Joachim Nesser; Francesco Faletra; Stefano De Castro; Martin Maron; Ayan R Patel; Natesa G Pandian
Journal:  Curr Cardiol Rep       Date:  2008-03       Impact factor: 3.955