The effectiveness of existing and modified cleaning regimens in a Welsh hospital.

C J Griffith1, P Obee, R A Cooper, N F Burton, M Lewis.   

Abstract

Hospital cleaning currently has a high media profile. The effectiveness of an existing ward-cleaning regimen was assessed at selected sites over a 14 day period and shown to be highly variable. The cleaning regimen was subsequently modified in two stages, both changes involving a rinse stage and substituting cloths with disposable paper towels. One modification continued using the existing detergent; the other replaced detergent with a quaternary ammonium sanitiser. Both modifications yielded significantly lower and more consistent bacterial counts. Assessment of residual organic soil using adenosine triphosphate (ATP) detection demonstrated that failure rates (measurements exceeding benchmark clean value of 500 relative light units (RLU)) fell from 86-100% after existing cleaning methods, to 0-14% after modified cleaning. Maximum ATP readings fell from 163,870 to 2289 RLU. Incorporating a quaternary ammonium sanitiser into the cleaning regimen produced a further slight, but not significant, improvement in cleaning efficacy. These findings suggest that simple improvements can be made to existing cleaning regimens to increase their efficacy.

Entities:  

Mesh:

Year:  2007        PMID: 17655976     DOI: 10.1016/j.jhin.2007.05.016

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  13 in total

1.  Environmental and body contamination from cleaning vomitus in a health care setting: A simulation study.

Authors:  Linh Phan; Yu-Min Su; Rachel Weber; Charissa Fritzen-Pedicini; Osayuwamen Edomwande; Rachael M Jones
Journal:  Am J Infect Control       Date:  2017-11-22       Impact factor: 2.918

2.  epic3: national evidence-based guidelines for preventing healthcare-associated infections in NHS hospitals in England.

Authors:  H P Loveday; J A Wilson; R J Pratt; M Golsorkhi; A Tingle; A Bak; J Browne; J Prieto; M Wilcox
Journal:  J Hosp Infect       Date:  2014-01       Impact factor: 3.926

3.  Adenosine triphosphate bioluminescence for bacteriologic surveillance and reprocessing strategies for minimizing risk of infection transmission by duodenoscopes.

Authors:  Saurabh Sethi; Robert J Huang; Monique T Barakat; Niaz Banaei; Shai Friedland; Subhas Banerjee
Journal:  Gastrointest Endosc       Date:  2016-11-03       Impact factor: 9.427

4.  Hygienic monitoring in long-term care facilities using ATP, crAssphage, and human noroviruses to direct environmental surface cleaning.

Authors:  Jennifer L Cannon; Geun Woo Park; Benjamin Anderson; Cortney Leone; Morgan Chao; Jan Vinjé; Angela M Fraser
Journal:  Am J Infect Control       Date:  2022-03       Impact factor: 2.918

5.  Improved eradication of Clostridium difficile spores from toilets of hospitalized patients using an accelerated hydrogen peroxide as the cleaning agent.

Authors:  Michelle J Alfa; Evelyn Lo; Alana Wald; Christine Dueck; Pat DeGagne; Godfrey K M Harding
Journal:  BMC Infect Dis       Date:  2010-09-15       Impact factor: 3.090

6.  Can measuring environmental cleanliness using ATP aid in the monitoring of wards with periods of increased incidence of Clostridium difficile?

Authors:  Katherine Hardy; Gill Abbott; Sarah Bashford; Helen Bucior; Jane Codd; Madelaine Holland; Mandy Reynolds; Avril Simms; Diane Thomlinson
Journal:  J Infect Prev       Date:  2013-08-23

7.  Healthcare environments and spatial variability of healthcare associated infection risk: cross-sectional surveys.

Authors:  Jean Gaudart; Elaine Cloutman-Green; Serge Guillas; Nikki D'Arcy; John C Hartley; Vanya Gant; Nigel Klein
Journal:  PLoS One       Date:  2013-09-19       Impact factor: 3.240

8.  Controlling methicillin-resistant Staphylococcus aureus (MRSA) in a hospital and the role of hydrogen peroxide decontamination: an interrupted time series analysis.

Authors:  Brett G Mitchell; Wilhelmine Digney; Phil Locket; Stephanie J Dancer
Journal:  BMJ Open       Date:  2014-04-19       Impact factor: 2.692

9.  Effectiveness of visual inspection compared with non-microbiologic methods to determine the thoroughness of post-discharge cleaning.

Authors:  Graham M Snyder; Aleah D Holyoak; Katharine E Leary; Bernadette F Sullivan; Roger B Davis; Sharon B Wright
Journal:  Antimicrob Resist Infect Control       Date:  2013-10-02       Impact factor: 4.887

10.  Influence of ventilation use and occupant behaviour on surface microorganisms in contemporary social housing.

Authors:  T Sharpe; G McGill; S J Dancer; M-F King; L Fletcher; C J Noakes
Journal:  Sci Rep       Date:  2020-07-16       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.