Literature DB >> 17655975

Rapid recontamination with MRSA of the environment of an intensive care unit after decontamination with hydrogen peroxide vapour.

K J Hardy1, S Gossain, N Henderson, C Drugan, B A Oppenheim, F Gao, P M Hawkey.   

Abstract

Meticillin-resistant Staphylococcus aureus (MRSA) persists in the hospital environment and conventional cleaning procedures do not necessarily eliminate contamination. A prospective study was conducted on an intensive care unit to establish the level of environmental contamination with MRSA, assess the effectiveness of hydrogen peroxide vapour (HPV) decontamination and determine the rate of environmental recontamination. MRSA was isolated from 11.2% of environmental sites in the three months preceding the use of HPV and epidemiological typing revealed that the types circulating within the environment were similar to those colonising patients. After patient discharge and terminal cleaning using conventional methods, MRSA was isolated from five sites (17.2%). After HPV decontamination but before the readmission of patients, MRSA was not isolated from the environment. Twenty-four hours after readmitting patients, including two colonized with MRSA, the organism was isolated from five sites. The strains were indistinguishable from a strain with which a patient was colonized but were not all confined to the immediate vicinity of the colonized patient. In the eight weeks after the use of HPV, the environment was sampled on a weekly basis and MRSA was isolated from 16.3% sites. Hydrogen peroxide vapour is effective in eliminating bacteria from the environment but the rapid rate of recontamination suggests that it is not an effective means of maintaining low levels of environmental contamination in an open-plan intensive care unit.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17655975     DOI: 10.1016/j.jhin.2007.05.009

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  19 in total

1.  Use of vaporized hydrogen peroxide decontamination during an outbreak of multidrug-resistant Acinetobacter baumannii infection at a long-term acute care hospital.

Authors:  Amy Ray; Federico Perez; Amanda M Beltramini; Marta Jakubowycz; Patricia Dimick; Michael R Jacobs; Kathy Roman; Robert A Bonomo; Robert A Salata
Journal:  Infect Control Hosp Epidemiol       Date:  2010-10-25       Impact factor: 3.254

Review 2.  MRSA and the environment: implications for comprehensive control measures.

Authors:  N Cimolai
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2008-02-14       Impact factor: 3.267

Review 3.  Hospital cleaning in the 21st century.

Authors:  S J Dancer
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-04-17       Impact factor: 3.267

4.  Editorial commentary: climbing the evidentiary hierarchy for environmental infection control.

Authors:  L Clifford McDonald; Matthew Arduino
Journal:  Clin Infect Dis       Date:  2012-10-05       Impact factor: 9.079

Review 5.  Controlling hospital-acquired infection: focus on the role of the environment and new technologies for decontamination.

Authors:  Stephanie J Dancer
Journal:  Clin Microbiol Rev       Date:  2014-10       Impact factor: 26.132

Review 6.  Community-associated methicillin-resistant Staphylococcus aureus: epidemiology and clinical consequences of an emerging epidemic.

Authors:  Michael Z David; Robert S Daum
Journal:  Clin Microbiol Rev       Date:  2010-07       Impact factor: 26.132

7.  Five-year microbiological monitoring of wards and operating theatres in southern Italy.

Authors:  V La Fauci; C Genovese; A Facciolà; M A R Palamara; R Squeri
Journal:  J Prev Med Hyg       Date:  2017-06

8.  Staphylococcal interspersed repeat unit typing of Staphylococcus aureus: evaluation of a new multilocus variable-number tandem-repeat analysis typing method.

Authors:  Teresa Conceição; Marta Aires de Sousa; Hermínia de Lencastre
Journal:  J Clin Microbiol       Date:  2009-03-04       Impact factor: 5.948

9.  Outbreak of clonal complex 22 Panton-Valentine leucocidin-positive methicillin-resistant Staphylococcus aureus.

Authors:  Mark I Garvey; Craig W Bradley; Kerry L Holden; Beryl Oppenheim
Journal:  J Infect Prev       Date:  2017-03-14

10.  Antimicrobial activity of novel nanostructured Cu-SiO2 coatings prepared by chemical vapour deposition against hospital related pathogens.

Authors:  Sajnu Varghese; Souad O Elfakhri; David W Sheel; Paul Sheel; Frederick J Eric Bolton; Howard A Foster
Journal:  AMB Express       Date:  2013-09-05       Impact factor: 3.298

View more