Literature DB >> 17654905

Log transformation benefits parameter estimation in microwave tomographic imaging.

Paul M Meaney1, Qianqian Fang, Tonny Rubaek, Eugene Demidenko, Keith D Paulsen.   

Abstract

Microwave tomographic imaging falls under a broad category of nonlinear parameter estimation methods when a Gauss-Newton iterative reconstruction technique is used. A fundamental requirement in using these approaches is evaluating the appropriateness of the regression model. While there have been numerous investigations of regularization techniques to improve overall image quality, few, if any, studies have explored the underlying statistical properties of the model itself. The ordinary least squares (OLS) approach is used most often, but there are other options such as the weighted least squares (WLS), maximum likelihood (ML), and maximum a posteriori (MAP) that may be more appropriate. In addition, a number of variance stabilizing transformations can be applied to make the inversion intrinsically more linear. In this paper, a statistical analysis is performed of the properties of the residual errors from the reconstructed images utilizing actual measured data and it is demonstrated that the OLS algorithm with a log transformation (OLSlog) is clearly advantageous relative to the more commonly used OLS approach by itself. In addition, several high contrast imaging experiments are performed, which demonstrate that different subsets of data are emphasized in each method and may contribute to the overall image quality differences.

Entities:  

Mesh:

Year:  2007        PMID: 17654905     DOI: 10.1118/1.2737264

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  Application of Two-Dimensional Discrete Dipole Approximation in Simulating Electric Field of a Microwave Breast Imaging System.

Authors:  Samar Hosseinzadegan; Andreas Fhager; Mikael Persson; Paul M Meaney
Journal:  IEEE J Electromagn RF Microw Med Biol       Date:  2018-11-21

2.  Microwave tomography in the context of complex breast cancer imaging.

Authors:  Paul M Meaney; Margaret W Fanning; Roberta M di Florio-Alexander; Peter A Kaufman; Shireen D Geimer; Tian Zhou; Keith D Paulsen
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

3.  3-D Microwave Tomography Using the Soft Prior Regularization Technique: Evaluation in Anatomically Realistic MRI-Derived Numerical Breast Phantoms.

Authors:  Amir H Golnabi; Paul M Meaney; Shireen D Geimer; Keith D Paulsen
Journal:  IEEE Trans Biomed Eng       Date:  2019-01-10       Impact factor: 4.538

4.  A systematic investigation of reflectance diffuse optical tomography using nonlinear reconstruction methods and continuous wave measurements.

Authors:  Zhen Yuan; Jiang Zhang; Xiaodong Wang; Changqing Li
Journal:  Biomed Opt Express       Date:  2014-08-12       Impact factor: 3.732

5.  3D parallel-detection microwave tomography for clinical breast imaging.

Authors:  N R Epstein; P M Meaney; K D Paulsen
Journal:  Rev Sci Instrum       Date:  2014-12       Impact factor: 1.523

6.  Electrical Characterization of Glycerin: Water Mixtures: Implications for Use as a Coupling Medium in Microwave Tomography.

Authors:  Paul M Meaney; Colleen J Fox; Shireen D Geimer; Keith D Paulsen
Journal:  IEEE Trans Microw Theory Tech       Date:  2017-01-31       Impact factor: 3.599

7.  3D microwave tomography of the breast using prior anatomical information.

Authors:  Amir H Golnabi; Paul M Meaney; Keith D Paulsen
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

8.  Clinical microwave tomographic imaging of the calcaneus: a first-in-human case study of two subjects.

Authors:  Paul M Meaney; Douglas Goodwin; Amir H Golnabi; Tian Zhou; Matthew Pallone; Shireen D Geimer; Gregory Burke; Keith D Paulsen
Journal:  IEEE Trans Biomed Eng       Date:  2012-07-17       Impact factor: 4.538

9.  Two-step inversion with a logarithmic transformation for microwave breast imaging.

Authors:  Paul M Meaney; Shireen D Geimer; Keith D Paulsen
Journal:  Med Phys       Date:  2017-07-17       Impact factor: 4.071

10.  Microwave thermal imaging of scanned focused ultrasound heating: phantom results.

Authors:  Paul M Meaney; Tian Zhou; Margaret W Fanning; Shireen D Geimer; Keith D Paulsen
Journal:  Int J Hyperthermia       Date:  2008-11       Impact factor: 3.914

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.