Calibration of a proton beam energy monitor.

M F Moyers1, G B Coutrakon, A Ghebremedhin, K Shahnazi, P Koss, E Sanders.   

Abstract

Delivery of therapeutic proton beams requires an absolute energy accuracy of +/-0.64 to 0.27 MeV for patch fields and a relative energy accuracy of +/-0.10 to 0.25 MeV for tailoring the depth dose distribution using the energy stacking technique. Achromatic switchyard tunes, which lead to better stability of the beam incident onto the patient, unfortunately limit the ability of switchyard magnet tesla meters to verify the correct beam energy within the tolerances listed above. A new monitor to measure the proton energy before each pulse is transported through the switchyard has been installed into a proton synchrotron. The purpose of this monitor is to correct and/or inhibit beam delivery when the measured beam energy is outside of the tolerances for treatment. The monitor calculates the beam energy using data from two frequency and eight beam position monitors that measure the revolution frequency of the proton bunches and the effective offset of the orbit from the nominal radius of the synchrotron. The new energy monitor has been calibrated by measuring the range of the beam through water and comparing with published range-energy tables for various energies. A relationship between depth dose curves and range-energy tables was first determined using Monte Carlo simulations of particle transport and energy deposition. To reduce the uncertainties associated with typical scanning water phantoms, a new technique was devised in which the beam energy was scanned while fixed thickness water tanks were sandwiched between two fixed parallel plate ionization chambers. Using a multitude of tank sizes, several energies were tested to determine the nominal accelerator orbit radius. After calibration, the energy reported by the control system matched the energy derived by range measurements to better than 0.72 MeV for all nine energies tested between 40 and 255 MeV with an average difference of -0.33 MeV. A study of different combinations of revolution frequency and radial offsets to test the envelope of algorithm accuracy demonstrated a relative accuracy of +/-0.11 MeV for small energy changes between 126 and 250 MeV. These new measurements may serve as a data set for benchmarking range-energy relationships.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17654898     DOI: 10.1118/1.2717382

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Energy spectrum control for modulated proton beams.

Authors:  Wen C Hsi; Michael F Moyers; Dmitri Nichiporov; Vladimir Anferov; Mark Wolanski; Chris E Allgower; Jonathan B Farr; Anthony E Mascia; Andries N Schreuder
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

2.  Experimental depth dose curves of a 67.5 MeV proton beam for benchmarking and validation of Monte Carlo simulation.

Authors:  Bruce A Faddegon; Jungwook Shin; Carlos M Castenada; José Ramos-Méndez; Inder K Daftari
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

3.  Reducing stray radiation dose to patients receiving passively scattered proton radiotherapy for prostate cancer.

Authors:  Phillip J Taddei; Jonas D Fontenot; Yuanshui Zheng; Dragan Mirkovic; Andrew K Lee; Uwe Titt; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2008-03-27       Impact factor: 3.609

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.