Literature DB >> 17654570

On the application of chemical shift-based multipoint water-fat separation methods in balanced SSFP imaging.

Hyeonjin Kim1, Alexander B Pinus, Jinghua Wang, Philip S Murphy, R Todd Constable.   

Abstract

Chemical shift-based multipoint water-fat separation methods have been applied in balanced steady-state free precession (bSSFP) sequences because of the high signal-to-noise-ratio (SNR) attainable. In this approach the echo formation is approximated to occur concurrently for both water and fat at an echo time (TE) equal to half the repetition time (TR/2 approximation). However, the degree to which the imaging conditions underlying the TR/2 approximation are satisfied can significantly vary in vivo depending upon the imaging region of interest (ROI) and the pixels across a field of view (FOV). The consequence of the TR/2 approximation on chemical shift-based multipoint water-fat separation was investigated. The influence of a mismatch between the pass-band profiles of water and fat (pass-band mismatch) on fat quantification was also examined. Theoretical and experimental results demonstrate that the TR/2 approximation can result in spatially dependent noise performance of multipoint water-fat separation methods, and the pass-band mismatch can render the precision of fat quantification spatially dependent. Given that local tissue characteristics in affected liver can be substantially variable, this study is of particular importance in liver imaging.

Entities:  

Mesh:

Year:  2007        PMID: 17654570     DOI: 10.1002/mrm.21303

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Comparative MR study of hepatic fat quantification using single-voxel proton spectroscopy, two-point dixon and three-point IDEAL.

Authors:  Hyeonjin Kim; Sara E Taksali; Sylvie Dufour; Douglas Befroy; T Robin Goodman; Kitt Falk Petersen; Gerald I Shulman; Sonia Caprio; R Todd Constable
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

2.  Magnetization-prepared IDEAL bSSFP: a flow-independent technique for noncontrast-enhanced peripheral angiography.

Authors:  Tolga Cukur; Ann Shimakawa; Huanzhou Yu; Brian A Hargreaves; Bob S Hu; Dwight G Nishimura; Jean H Brittain
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

3.  Fat-water separation in dynamic objects using an UNFOLD-like temporal processing.

Authors:  Riad Ababneh; Jing Yuan; Bruno Madore
Journal:  J Magn Reson Imaging       Date:  2010-10       Impact factor: 4.813

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.