Literature DB >> 17652732

Anisometropic amblyopia: spatial contrast sensitivity deficits in inferred magnocellular and parvocellular vision.

Andrew J Zele1, Joel Pokorny, David Y Lee, Dennis Ireland.   

Abstract

PURPOSE: To measure achromatic spatial contrast sensitivity in patients with anisometropic amblyopia under conditions favoring inferred parvocellular (PC) or magnocellular (MC) pathway mediation.
METHODS: Fourteen anisometropic amblyopes (VA amblyopic eye 6/12 or lower; better eye greater than 6/7.5) and 10 age-matched, nonamplyopic controls (VA 6/6) participated. Foveal spatial contrast sensitivity was measured using localized, spatially narrow band targets (0.25-8.0 cpd) presented in the center of a steady pedestal (favoring MC detection) or a pulsed pedestal (favoring PC detection) that was set within a uniform surround.
RESULTS: Spatial contrast sensitivity functions were bandpass for the steady-pedestal and lowpass for the pulsed-pedestal. Under steady-pedestal adaptation, the amblyopes showed reduced spatial contrast sensitivity at intermediate frequencies (1-2 cpd), consistent with MC sensitivity loss. For the pulsed-pedestal condition, a generalized loss of sensitivity was observed across all spatial frequencies (0.5-4 cpd), consistent with PC sensitivity loss. The magnitudes of inferred MC and PC loss were similar. In the steady- and pulsed-pedestal paradigms, results for the better eye of greater than 75% of the amblyopes were normal or near normal at low and intermediate spatial frequencies.
CONCLUSIONS: Anisometropic amblyopia produces spatial contrast sensitivity losses in inferred PC- and MC-mediated vision, suggesting there may be anomalous processing of MC and PC signals in higher visual areas, including those with orientation and spatial frequency selective cells in the visual cortex. With spatially localized stimuli and a paradigm designed to distinguish between MC and PC vision under conditions that differ only in the interstimulus adaptation, the better eye of the amblyopes was normal or near normal.

Entities:  

Mesh:

Year:  2007        PMID: 17652732     DOI: 10.1167/iovs.06-1207

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  14 in total

1.  Chromatic and luminance contrast sensitivity in fullterm and preterm infants.

Authors:  Rain G Bosworth; Karen R Dobkins
Journal:  J Vis       Date:  2009-12-14       Impact factor: 2.240

2.  Effects of prematurity on the development of contrast sensitivity: testing the visual experience hypothesis.

Authors:  Rain G Bosworth; Karen R Dobkins
Journal:  Vision Res       Date:  2013-02-24       Impact factor: 1.886

3.  Anisometropia magnitude and visual deficits in previously untreated anisometropic amblyopia.

Authors:  Bin-Bin Chen; Feng-Wei Song; Zhao-Hui Sun; Yi Yang
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

4.  Effects of gestational length, gender, postnatal age, and birth order on visual contrast sensitivity in infants.

Authors:  Karen R Dobkins; Rain G Bosworth; Joseph P McCleery
Journal:  J Vis       Date:  2009-09-30       Impact factor: 2.240

5.  Alternative Flicker Glass: A New Anti-Suppression Approach to the Treatment of Anisometropic Amblyopia.

Authors:  Ying Yuan; Chengcheng Zhu; Peng Wang; Xiaojun Hu; Wenbo Yao; Xinhui Huang; Bilian Ke
Journal:  Ophthalmic Res       Date:  2021-03-02       Impact factor: 2.892

6.  Alterations induced by bangerter filters on the visual field: a frequency doubling technology and standard automated perimetry study.

Authors:  Costantino Schiavi; Filippo Tassi; Alessandro Finzi; Mauro Cellini
Journal:  J Ophthalmol       Date:  2015-01-20       Impact factor: 1.909

7.  Comparison of the Wave Amplitude of Visually Evoked Potential in Amblyopic Eyes between Patients with Esotropia and Anisometropia and a Normal Group.

Authors:  Mohammad Reza Talebnejad; Saeedeh Hosseinmenni; Ebrahim Jafarzadehpur; Ali Mirzajani; Enayatollah Osroosh
Journal:  Iran J Med Sci       Date:  2016-03

8.  Monocular blur alters the tuning characteristics of stereopsis for spatial frequency and size.

Authors:  Roger W Li; Kayee So; Thomas H Wu; Ashley P Craven; Truyet T Tran; Kevin M Gustafson; Dennis M Levi
Journal:  R Soc Open Sci       Date:  2016-09-21       Impact factor: 2.963

9.  Steady-state pattern electroretinogram and frequency doubling technology in anisometropic amblyopia.

Authors:  Costantino Schiavi; Filippo Tassi; Alessandro Finzi; Ernesto Strobbe; Mauro Cellini
Journal:  Clin Ophthalmol       Date:  2016-10-19

10.  Luminance noise as a novel approach for measuring contrast sensitivity within the magnocellular and parvocellular pathways.

Authors:  Cierra M Hall; J Jason McAnany
Journal:  J Vis       Date:  2017-07-01       Impact factor: 2.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.