[Evaluation of 2D and 3D MRI imaging in the diagnosis of pancreatic carcinoma].

Dong-qing Wang1, Meng-su Zeng, Da-yong Jin, Wen-hui Lou, Yuan Ji, Sheng-xiang Rao, Cai-zhong Chen, Ren-chen Li.   

Abstract

OBJECTIVE: To evaluate various kinds of sequences and modified dynamic contrast-enhanced MRI methods in the diagnosis of pancreatic carcinoma.
METHODS: Forty-nine pancreatic carcinoma patients proved by histopathology or clinical examination and follow-up underwent MR examination. Plain MR sequences included: T1-weighted 2D FLASH, T1 WI 3D VIBE, TSE T2 WI and HASTE with FS. Modified dynamic contrast-enhanced scanning procedures were coronal scaning with 3D FLASH and axial scaning using T1 WI 3D VIBE sequences in turn for the upper abdominal area and pancreatic area. The coronal imaging were used to obtain 3D peripancreatic vessels during arterial phase and portal vein phase scanning, respectively. The axial imaging were used to detect the tumor in pancreatic parenchymal phase and delayed phase scanning, respectively. Final scanning for the whole upper abdomen was performed using T1 WI 2D FLASH axial sequence.
RESULTS: (1) Of 49 lesions in these patients, 45 showed hypo-intensity and 4 iso-intensity on 3D VIBE. Forty-six lesions showed hypo-intensity and 3 isointensity on 2D FLASH. On TSE T2 + FS, lesion contour was not clear enough; 3 of them displayed isointensity, the other showed iso- or hyper-intensity. (2) During pancreatic parenchymal phase, 48 lesions showed hypo-intensity and 39 ring enhancement. Twenty-four lesions displayed marginal tubercle and inner compartment enhancement during portal vein and delayed phase. Six lesions showed iso- or hyper-intensity in delayed phase. (3) Thirty-seven patients underwent surgical exploration. MRI and MRA had a good correlation with surgical findings for peripancreatic vessels which were diagnosed as being invasive or noninvasive by tumors except three superior mesenteric arteries and four superior mesenteric veins being misdiagnosed.
CONCLUSION: As"one-stop-shop" MRI examination, modified MRI sequences consisting of dynamic coronal and axial contrast-enhanced scanning is feasible and helpful in diagnosing, staging and assessing the resectability for pancreatic carcinoma.

Entities:  

Mesh:

Year:  2007        PMID: 17649641

Source DB:  PubMed          Journal:  Zhonghua Zhong Liu Za Zhi        ISSN: 0253-3766