Literature DB >> 17646362

Three-dimensional sonographic morphologic assessment of adnexal masses: a reproducibility study.

Juan Luis Alcázar1, Manuel García-Manero, Rosendo Galván.   

Abstract

OBJECTIVE: The purpose of this study was to assess the reproducibility of 3-dimensional (3D) sonography for classifying adnexal masses.
METHODS: Eighty-two consecutive women with the diagnosis of an adnexal mass on 2-dimensional transvaginal sonography were reevaluated by 3D sonography, and 3D volume data from each mass were stored. Two different examiners (6 years and 1 year of experience in 3D sonography, respectively) reviewed 3D sonograms 1 month after the last patient was recruited and then 1 week later again. Masses had to be classified as benign or malignant. Criteria suggestive of malignancy were the presence of a thick wall, gross papillary projections, solid areas, and solid echogenicity. A definitive histologic diagnosis was obtained in every case. Intraobserver and interobserver agreement was estimated by calculating the Cohen kappa index.
RESULTS: Twenty-seven (33%) tumors were malignant, and 55 (67%) were benign. Intraobserver agreement for both examiners was good (kappa = 0.78 and 0.72, respectively). Interobserver agreement was also good (kappa = 0.70).
CONCLUSIONS: Three-dimensional sonography is a reproducible technique for morphologic assessment of adnexal masses.

Entities:  

Mesh:

Year:  2007        PMID: 17646362     DOI: 10.7863/jum.2007.26.8.1007

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  4 in total

Review 1.  Role of Three-Dimensional Ultrasound in Gynecology.

Authors:  Engin Turkgeldi; Bulent Urman; Baris Ata
Journal:  J Obstet Gynaecol India       Date:  2014-11-08

2.  HDlive rendering image of adnexal tumors: preliminary report.

Authors:  Toshiyuki Hata; Kenji Kanenishi; Masato Mashima; Emiko Nitta; Nobuhiro Mori; Uiko Hanaoka; Hirokazu Tanaka
Journal:  J Med Ultrason (2001)       Date:  2013-08-31       Impact factor: 1.314

3.  Detection of focal liver lesions: from the subjectivity of conventional ultrasound to the objectivity of volume ultrasound.

Authors:  F Vecchiato; M D'Onofrio; R Malagò; E Martone; A Gallotti; N Faccioli; V Cantisani; C Marigliano; A Ruzzenente; R Pozzi Mucelli
Journal:  Radiol Med       Date:  2009-06-23       Impact factor: 3.469

4.  The Reproducibility of Ultrasonographic Findings of Rectosigmoid Endometriosis Among Examiners With Different Level of Expertise.

Authors:  Stefano Guerriero; MariaAngela Pascual; Silvia Ajossa; Manuela Neri; Monica Pilloni; Betlem Graupera; Ignacio Rodriguez; Juan Luis Alcazar
Journal:  J Ultrasound Med       Date:  2021-04-10       Impact factor: 2.754

  4 in total