Literature DB >> 17646225

Electromagnetic navigation bronchoscopy-guided fiducial placement for robotic stereotactic radiosurgery of lung tumors: a feasibility study.

Devanand Anantham1, David Feller-Kopman, Lakshmi N Shanmugham, Stuart M Berman, Malcolm M DeCamp, Sidhu P Gangadharan, Ralf Eberhardt, Felix Herth, Armin Ernst.   

Abstract

BACKGROUND: Stereotactic radiosurgery (Cyberknife; Accuray Incorporated; Sunnyvale, CA) is a treatment option for patients who are medically unfit to undergo lung tumor resection. For precise tumor ablation, the Cyberknife requires fiducial marker placement in or near the target tumor. Fiducial placement under transthoracic CT guidance is associated with a high risk of iatrogenic pneumothorax. Electromagnetic navigation bronchoscopy (ENB) may offer a less morbid alternative to accurately deploy fiducials to bronchoscopically invisible peripheral lung lesions.
OBJECTIVE: Open-label, feasibility study to assess fiducial placement in peripheral lung tumors by ENB.
METHOD: Consecutive patients with peripheral lung tumors and who were evaluated to be nonsurgical candidates underwent fiducial placement under ENB. This procedure was considered successful if fiducials were placed in or near the tumors and remained in place without migration for radiosurgery to proceed. The need for alternative or additional intrathoracic fiducial placement was documented as procedure failure.
RESULTS: A total of 39 fiducials markers were successfully deployed in eight of nine patients (89%). Of these eight successful cases, seven had fiducials placed directly within the tumor (88%). At Cyberknife planning, 7 to 10 days after fiducial placement, 35 of 39 fiducial markers (90%) were still in place and were adequate to allow radiosurgery to proceed. No immediate bronchoscopic complications were observed. One patient had a COPD exacerbation. Another patient returned within 1 day with transient, self-limiting fever.
CONCLUSIONS: ENB can be used to deploy fiducial markers for Cyberknife radiosurgery of lung tumors safely and accurately without the complications associated with transthoracic placement.

Entities:  

Mesh:

Year:  2007        PMID: 17646225     DOI: 10.1378/chest.07-0522

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  37 in total

1.  Correlation and prediction uncertainties in the cyberknife synchrony respiratory tracking system.

Authors:  Eric W Pepin; Huanmei Wu; Yuenian Zhang; Bryce Lord
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

Review 2.  Navigation bronchoscopy for diagnosis and small nodule location.

Authors:  Juan A Muñoz-Largacha; Virginia R Litle; Hiran C Fernando
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

Review 3.  Image-guided techniques for localizing pulmonary nodules in thoracoscopic surgery.

Authors:  Mong-Wei Lin; Jin-Shing Chen
Journal:  J Thorac Dis       Date:  2016-10       Impact factor: 2.895

4.  Localizing small lung lesions in video-assisted thoracoscopic surgery via radiofrequency identification marking.

Authors:  Yojiro Yutaka; Toshihiko Sato; Jitian Zhang; Koichi Matsushita; Hiroyuki Aiba; Yusuke Muranishi; Yasuto Sakaguchi; Teruya Komatsu; Fumitsugu Kojima; Tatsuo Nakamura; Hiroshi Date
Journal:  Surg Endosc       Date:  2016-12-23       Impact factor: 4.584

5.  Improved targeting accuracy of lung tumor biopsies with scanning-beam digital x-ray tomosynthesis image guidance.

Authors:  Geoff Nelson; Meng Wu; Cameron Hinkel; Ganesh Krishna; Tobias Funk; Jarrett Rosenberg; Rebecca Fahrig
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

Review 6.  Multidetector CT and postprocessing in planning and assisting in minimally invasive bronchoscopic airway interventions.

Authors:  Arjun Nair; Myrna C Godoy; Emma L Holden; Brendan P Madden; Felix Chua; David E Ost; Justus E Roos; David P Naidich; Ioannis Vlahos
Journal:  Radiographics       Date:  2012 Sep-Oct       Impact factor: 5.333

7.  Electromagnetic navigation bronchoscopy: A descriptive analysis.

Authors:  Steven Leong; Hong Ju; Henry Marshall; Rayleen Bowman; Ian Yang; Ann-Maree Ree; Cathy Saxon; Kwun M Fong
Journal:  J Thorac Dis       Date:  2012-04-01       Impact factor: 2.895

Review 8.  Hybrid theatre and alternative localization techniques in conventional and single-port video-assisted thoracoscopic surgery.

Authors:  Ze-Rui Zhao; Rainbow W H Lau; Calvin S H Ng
Journal:  J Thorac Dis       Date:  2016-03       Impact factor: 2.895

Review 9.  Role of electromagnetic navigational bronchoscopy in pulmonary nodule management.

Authors:  Aditya Goud; Chanukya Dahagam; David P Breen; Saiyad Sarkar
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

Review 10.  Electromagnetic navigation guided bronchoscopy.

Authors:  Douglas Arenberg
Journal:  Cancer Imaging       Date:  2009-11-06       Impact factor: 3.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.