Literature DB >> 17646103

Analysis of accuracy of kyphotic angle measurement for vertebral osteoporotic compression fractures.

Sang Won Lee1, Jae Taek Hong, Byung Chul Son, Jae Hoon Sung, Il Sub Kim, Chun Kun Park.   

Abstract

A reliable and reproducible measurement technique for the sagittal contour in vertebral fractures is paramount to clinical decision-making. This study was designed to determine the most reliable measurement technique in osteoporotic vertebral compression fracture. Fifteen lateral radiographs of thoracic and lumbar fractures were selected and measured on two separate occasions by three spine surgeons using six different measurement techniques (centroid, Harrison posterior tangent method and 4 different types of modified Cobb method). The radiograph quality was assessed and the center beam location was determined. The inter- and intraobserver variance of the Cobb method 4 and the Harrison posterior tangent method were significantly lower than for the other four methods. The intraobserver correlation coefficients were the most consistent using the Cobb method 4 (0.982), followed by the Harrison posterior tangent method (0.953) and Cobb method 1 (0.874). The intraobserver agreement (% of repeated measures within 5 degrees of the original measurement) ranged from 42% to 98% for each technique for all three observers, with the Cobb method 4 showing the best agreement (97.8%) followed by the Harrison posterior tangent method (93.7%). The Cobb method 4 and Harrison posterior tangent method, when applied to measuring the kyphosis, were reliable and had a similar small error range. The Cobb method 4 showed the best overall reliability. The centroid method and the other Cobb methods using a fractured endplate did not produce an accurate result due to inter- and intraobserver differences in determining the baseline.

Entities:  

Mesh:

Year:  2007        PMID: 17646103     DOI: 10.1016/j.jocn.2006.08.005

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  3 in total

1.  Inter- and intraobserver reliability of the vertebral, local and segmental kyphosis in 120 traumatic lumbar and thoracic burst fractures: evaluation in lateral X-rays and sagittal computed tomographies.

Authors:  Benjamin Ulmar; Alexander Brunner; Markus Gühring; Traude Schmälzle; Kuno Weise; Andreas Badke
Journal:  Eur Spine J       Date:  2009-12-02       Impact factor: 3.134

2.  Reliability of novice physiotherapists for measuring Cobb angle using a digital method.

Authors:  Patcharawan Suwannarat; Pattra Wattanapan; Arpassanan Wiyanad; Pakwipa Chokphukiao; Sininat Wilaichit; Sugalya Amatachaya
Journal:  Hong Kong Physiother J       Date:  2017-03-31

3.  Accuracy and Reliability of X-ray Measurements in the Cervical Spine.

Authors:  Catarina Marques; Emma Granström; Anna MacDowall; Nuno Canto Moreira; Martin Skeppholm; Claes Olerud
Journal:  Asian Spine J       Date:  2019-11-01
  3 in total