Literature DB >> 17645556

Towards peakless, reproducible and long-acting insulins. An assessment of the basal analogues based on isoglycaemic clamp studies.

T Heise1, T R Pieber.   

Abstract

While the advantages of the two basal insulin analogues, glargine and detemir, over neutral protamine Hagedorn are well established, the relative merit of the two compared with each other has been a matter of some controversy. The two analogues are popularly perceived to differ from each other in their pharmacodynamic (PD) profiles, in particular with regard to 'flatness' and duration of action. The aim of this review, therefore, is to give a complete overview on the available PD data of both analogues as derived with the glucose clamp technique. In order to improve parity across studies, a common definition for duration of action (time from injection to plasma glucose >8.3 mmol/l) was applied and study data were recalculated when necessary. Despite differences in methodological details, the results of most clamp studies were very consistent. Glargine and detemir both typically show a gentle rise and fall in glucose-lowering action over time. Duration of action with both analogues is dose dependent, but in the clinically relevant range of 0.35-0.8 U/kg it is close to 24 h in people with type 1 diabetes and in excess of this in people with type 2 diabetes. While both analogues seem to be very similar with regard to the mean shape of their PD profile and duration of action, detemir shows less within-subject variability in its metabolic effect. These findings in experimental glucose clamp studies are consistent with observations in clinical trials and support routine once daily use with either analogue, in particular in people with type 2 diabetes.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17645556     DOI: 10.1111/j.1463-1326.2007.00756.x

Source DB:  PubMed          Journal:  Diabetes Obes Metab        ISSN: 1462-8902            Impact factor:   6.577


  53 in total

Review 1.  Insulin analogs: impact on treatment success, satisfaction, quality of life, and adherence.

Authors:  Israel Hartman
Journal:  Clin Med Res       Date:  2008-09-18

2.  How to Assess the Quality of Glucose Clamps? Evaluation of Clamps Performed With ClampArt, a Novel Automated Clamp Device.

Authors:  Carsten Benesch; Tim Heise; Oliver Klein; Lutz Heinemann; Sabine Arnolds
Journal:  J Diabetes Sci Technol       Date:  2015-04-07

3.  Long-term glycemic control and prevention of diabetes complications in vivo using oleic acid-grafted-chitosan‑zinc-insulin complexes incorporated in thermosensitive copolymer.

Authors:  Divya Sharma; Jagdish Singh
Journal:  J Control Release       Date:  2020-04-10       Impact factor: 9.776

Review 4.  Update on the treatment of type 2 diabetes mellitus.

Authors:  Juan José Marín-Peñalver; Iciar Martín-Timón; Cristina Sevillano-Collantes; Francisco Javier Del Cañizo-Gómez
Journal:  World J Diabetes       Date:  2016-09-15

5.  Clinical utility of insulin and insulin analogs.

Authors:  Ahter D Sanlioglu; Hasan Ali Altunbas; Mustafa Kemal Balci; Thomas S Griffith; Salih Sanlioglu
Journal:  Islets       Date:  2013-03-01       Impact factor: 2.694

6.  The interpretation of glucose clamp studies of long-acting insulin analogues: from physiology to marketing and back.

Authors:  S G H A Swinnen; F Holleman; J H DeVries
Journal:  Diabetologia       Date:  2008-08-01       Impact factor: 10.122

Review 7.  The role of insulin detemir in overweight type 2 diabetes management.

Authors:  Yared N Demssie; Naveed Younis; Handrean Soran
Journal:  Vasc Health Risk Manag       Date:  2009-06-29

Review 8.  How pharmacokinetic and pharmacodynamic principles pave the way for optimal basal insulin therapy in type 2 diabetes.

Authors:  S Arnolds; B Kuglin; C Kapitza; T Heise
Journal:  Int J Clin Pract       Date:  2010-07-05       Impact factor: 2.503

Review 9.  Insulin therapy for type 2 diabetes.

Authors:  Sanne G Swinnen; Joost B Hoekstra; J Hans DeVries
Journal:  Diabetes Care       Date:  2009-11       Impact factor: 19.112

10.  Tolerability, safety and adherence to treatment with insulin detemir injection in the treatment of type 2 diabetes.

Authors:  Athena Philis-Tsimikas
Journal:  Patient Prefer Adherence       Date:  2008-02-02       Impact factor: 2.711

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.