Abstract

OBJECT: Bioabsorbable polymeric material coils are being used in the endovascular treatment of aneurysms to achieve better thrombus organization than is possible using bare platinum coils. We used immunohistochemical and molecular biological analysis techniques in experimental aneurysms implanted with three different bioabsorbable polymer coils and platinum coils.
METHODS: The degradation kinetics of nine polymer candidates for further analysis were first analyzed in vitro, and three materials with different degradation rates were selected. Seventy-four aneurysms were created in 37 swine using the venous pouch technique. The aneurysms were surgically implanted with one of the materials as follows (time points = 3, 7, and 14 days): Group 1, Guglielmi detachable coils (platinum); Group 2, Polysorb (90:10 polyglycolic acid [PGA]/polylactic acid); Group 3, Maxon (PGA/trimethylene carbonate); and Group 4, poly-l-lactic acid. Histological, immunohistochemical, and cDNA microarray analyses were performed on tissue specimens.
RESULTS: Groups 1 and 4 showed minimal inflammatory response adjacent to the coil mass. In Group 2, Polysorb elicited a unique, firm granulation tissue that accelerated intraaneurysmal thrombus organization. In Group 3 intermediate inflammatory reactions were seen. Microarray analysis with Expression Analysis Sytematic Explorer software showed functional-cluster-gene activation to be increased at Day 7, preceding the histologic manifestation of polymer-induced granulation tissue at Day 14. A profile of expression changes in cytokine-related and extracellular membrane-related genes was compiled.
CONCLUSIONS: Degradation speed was not the only factor determining the strength of the biological response. Polysorb induced an early, unique granulation tissue that conferred greater mechanical strength to the intraaneurysmal coilthrombus complex. Enhancing the formation of this polymer-induced granulation tissue may provide a new direction for improving long-term anatomical outcomes in cases involving aneurysms embolized with detachable coils.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17639880     DOI: 10.3171/JNS-07/07/0109

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  11 in total

1.  In vitro performance of a shape memory polymer foam-coated coil embolization device.

Authors:  Anthony J Boyle; Mark A Wierzbicki; Scott Herting; Andrew C Weems; Adam Nathan; Wonjun Hwang; Duncan J Maitland
Journal:  Med Eng Phys       Date:  2017-07-31       Impact factor: 2.242

Review 2.  Design and biocompatibility of endovascular aneurysm filling devices.

Authors:  Jennifer N Rodriguez; Wonjun Hwang; John Horn; Todd L Landsman; Anthony Boyle; Mark A Wierzbicki; Sayyeda M Hasan; Douglas Follmer; Jesse Bryant; Ward Small; Duncan J Maitland
Journal:  J Biomed Mater Res A       Date:  2014-08-04       Impact factor: 4.396

Review 3.  Mechanisms of Healing in Coiled Intracranial Aneurysms: A Review of the Literature.

Authors:  W Brinjikji; D F Kallmes; R Kadirvel
Journal:  AJNR Am J Neuroradiol       Date:  2014-11-27       Impact factor: 3.825

4.  Contrast Enhancement of Intracranial Aneurysms on 3T 3D Black-Blood MRI and Its Relationship to Aneurysm Recurrence following Endovascular Treatment.

Authors:  S Elsheikh; H Urbach; S Meckel
Journal:  AJNR Am J Neuroradiol       Date:  2020-02-13       Impact factor: 3.825

Review 5.  Embolic Agents: Coils.

Authors:  Nicholas Xiao; Robert J Lewandowski
Journal:  Semin Intervent Radiol       Date:  2022-02-18       Impact factor: 1.513

6.  Immunohistochemical analysis of a ruptured basilar top aneurysm autopsied 22 years after embolization with Guglielmi detachable coils.

Authors:  Ichiro Yuki; Daniel Spitzer; Guido Guglielmi; Gary Duckwiler; Motoaki Fujimoto; Hiroyuki Takao; Reza Jahan; Satoshi Tateshima; Yuichi Murayama; Fernando Vinuela
Journal:  BMJ Case Rep       Date:  2014-07-23

Review 7.  Repair process in spontaneous intradural dissecting aneurysms in children: report of eight patients and review of the literature.

Authors:  Dittapong Songsaeng; Kittipong Srivatanakul; Frédérique Toulgoat; Guillaume Saliou; Augustin Ozanne; Pierre Lasjaunias
Journal:  Childs Nerv Syst       Date:  2008-08-19       Impact factor: 1.475

Review 8.  The development and the use of experimental animal models to study the underlying mechanisms of CA formation.

Authors:  Tomohiro Aoki; Masaki Nishimura
Journal:  J Biomed Biotechnol       Date:  2010-12-28

Review 9.  A Ruptured Basilar Tip Aneurysm Showing Repeated Perianeurysmal Edema after Endovascular Coil Embolization: Case Report.

Authors:  Tomonori Takeshita; Nobutaka Horie; Yutaka Fukuda; Gohei So; Kentaro Hayashi; Minoru Morikawa; Kazuhiko Suyama; Izumi Nagata
Journal:  Neurol Med Chir (Tokyo)       Date:  2013-12-27       Impact factor: 1.742

10.  Long Term Outcome after Application of the Angio-Seal Vascular Closure Device in Minipigs.

Authors:  Lisa Kabelitz; Andrea Nonn; Kay W Nolte; Omid Nikoubashman; Ahmed Othman; Sarah Heringer; Martin Kramer; Martin Wiesmann; Marc A Brockmann
Journal:  PLoS One       Date:  2016-09-28       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.