UNLABELLED: Seroma is one of the most frequent complications of PTFE vascular grafts and its etiology is still unclear. CASE REPORT: A 51 year-old male on regular dialytic treatment for seven years underwent the surgical implantation of a vascular prosthesis of homologous safena due to the thrombosis of his native artero-venous fistula. Several years earlier the patient had suffered the amputation of the left forearm because of electric shock. A few months later the vascular prosthesis was replaced with a PTFE vascular graft as a result of aneurysm formation and thrombosis. During the following days a non pulsating swelling occurred near the arterial anasto-mosis. Ultrasonography, doppler sonography and aspiration confirmed the diagnosis of seroma and it was surgically removed. Some weeks later a new seroma was observed in the same site and associated with a skin ulcer. A new surgical removal had no benefit and about one month later a perigraft collection was found along with signs of bacterial infection. For this reason the patient underwent the surgical excision of the PTFE graft and a vascular access was warranted by placing a Tesio TM catheter. Usually surgery is considered mandatory in seromas larger than 2 cm in diameter and showing continuous growth. In our patient the poor vascular status might have suggested a more conservative management even with a seroma diameter of about 7 cm. Nevertheless the high risk of systemic infection prompted us to remove the PTFE graft.

Entities:  

Year:  2001        PMID: 17638254     DOI: 10.1177/112972980100200106

Source DB:  PubMed          Journal:  J Vasc Access        ISSN: 1129-7298            Impact factor:   2.283


  2 in total

1.  Saphenous vein wrapping for the treatment of a perigraft seroma: report of a case.

Authors:  Yildirim Imren; Lawand Qaradaghi; Gursel Levent Oktar; Emrah Ereren; Naim Boran Tumer
Journal:  Surg Today       Date:  2011-03-23       Impact factor: 2.549

2.  Postoperative peri-axillary seroma following axillary artery cannulation for surgical treatment of acute type A aortic dissection.

Authors:  Efstratios E Apostolakis; Nikolaos G Baikoussis; Konstantinos Katsanos; Menelaos Karanikolas
Journal:  J Cardiothorac Surg       Date:  2010-05-25       Impact factor: 1.637

  2 in total