Literature DB >> 1763723

Assessing adequacy of collateral circulation during balloon test occlusion of the internal carotid artery with 99mTc-HMPAO SPECT.

L H Monsein1, P J Jeffery, B B van Heerden, Z Szabo, J R Schwartz, E E Camargo, J Chazaly.   

Abstract

A balloon test occlusion of the internal carotid artery was performed in 11 patients with internal carotid artery aneurysms. Tolerance by patients was assessed by a combination of clinical examination; angiography; electroencephalography; 99mTc-hexamethylpropyleneamine oxime (99mTc-HMPAO) single-photon emission computed tomography (SPECT) with relative quantification; and, in four patients, 99mTc-HMPAO SPECT with absolute quantification of cerebral blood flow. During test occlusion, angiography showed a patent circle of Willis in all patients. No patient developed new clinical findings or electroencephalographic changes. The SPECT studies of five patients in whom 99mTc-HMPAO was injected during test occlusion demonstrated changes from their baseline SPECT studies. The internal carotid artery was permanently occluded in two of these patients, neither of whom became symptomatic because of the occlusion. Three patients who demonstrated no changes between baseline and test occlusion SPECT studies underwent permanent occlusion of the internal carotid artery without incident, and postoperative SPECT images were unchanged from baseline. Our preliminary results suggest that patients who have no changes between baseline and test occlusion 99mTc-HMPAO SPECT studies should have adequate collateral circulation to sustain cerebral blood flow after occlusion of the internal carotid artery if no thromboembolic episodes occur. In contrast, a patient's tolerance of permanent occlusion cannot be consistently and reliably predicted if there are changes between baseline and test occlusion SPECT studies. In these patients, absolute quantitation of cerebral blood flow is important. Greater numbers of patients are required to confirm these initial results.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1763723      PMCID: PMC8331477     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  12 in total

1.  Carotid artery balloon test occlusion.

Authors: 
Journal:  AJNR Am J Neuroradiol       Date:  2001-09       Impact factor: 3.825

2.  Venous phase timing during balloon test occlusion as a criterion for permanent internal carotid artery sacrifice.

Authors:  Daniel Giansante Abud; Laurent Spelle; Michel Piotin; Charbel Mounayer; Jose Ricardo Vanzin; Jacques Moret
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

3.  Angiographic circulation time and cerebral blood flow during balloon test occlusion of the internal carotid artery.

Authors:  Kenichi Sato; Hiroaki Shimizu; Takashi Inoue; Miki Fujimura; Yasushi Matsumoto; Ryushi Kondo; Hidenori Endo; Yukihiko Sonoda; Teiji Tominaga
Journal:  J Cereb Blood Flow Metab       Date:  2013-10-09       Impact factor: 6.200

4.  Predictive value of balloon test occlusion of the internal carotid artery.

Authors:  D H Segal; C Sen; J B Bederson; P Catalano; M Sacher; A L Stollman; M Lorberboym
Journal:  Skull Base Surg       Date:  1995

5.  Cerebral blood flow and metabolism measurement using positron emission tomography before and during internal carotid artery test occlusions: feasibility of rapid quantitative measurement of CBF and OEF/CMRO(2).

Authors:  N Kawai; M Kawanishi; A Shindou; N Kudomi; Y Yamamoto; Y Nishiyama; T Tamiya
Journal:  Interv Neuroradiol       Date:  2012-09-10       Impact factor: 1.610

6.  Monitoring of balloon test occlusion of the internal carotid artery by parametric color coding and perfusion imaging within the angio suite: first results.

Authors:  T Struffert; Y Deuerling-Zheng; T Engelhorn; S Kloska; P Gölitz; A Bozzato; M Kapsreiter; C M Strother; A Doerfler
Journal:  Clin Neuroradiol       Date:  2013-03-23       Impact factor: 3.649

7.  Impact of cervical internal carotid clamping and radial artery graft bypass on cortical arterial perfusion pressure during craniotomy.

Authors:  Ken Kazumata; Hiroyasu Kamiyama; Tatsuya Ishikawa; Toshitaka Nakamura; Shunsuke Terasaka; Kiyohiro Houkin
Journal:  Neurosurg Rev       Date:  2014-04-04       Impact factor: 3.042

8.  Preoperative risk assessment for carotid occlusion by transcranial Doppler ultrasound.

Authors:  S Schneweis; H Urbach; L Solymosi; F Ries
Journal:  J Neurol Neurosurg Psychiatry       Date:  1997-05       Impact factor: 10.154

Review 9.  Monitoring balloon test occlusion of the internal carotid artery with transcranial Doppler. A case report and literature review.

Authors:  Orlando Galego; César Nunes; Ricardo Morais; João Sargento-Freitas; Francisco Sales; Egídio Machado
Journal:  Neuroradiol J       Date:  2014-02-24

10.  Changes in cerebral blood flow induced by balloon test occlusion of the internal carotid artery under hypotension.

Authors:  F Tanaka; S Nishizawa; Y Yonekura; N Sadato; K Ishizu; H Okazawa; N Tamaki; I Nakahara; W Taki; J Konishi
Journal:  Eur J Nucl Med       Date:  1995-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.