Literature DB >> 17636877

Performance of SU-8 microchips as separation devices and comparison with glass microchips.

Tiina Sikanen1, Liisa Heikkilä, Santeri Tuomikoski, Raimo A Ketola, Risto Kostiainen, Sami Franssila, Tapio Kotiaho.   

Abstract

Effective analytical performance of native, all-SU-8 separation microdevices is addressed by comparing their performance to commercial glass microdevices in microchip zone electrophoresis accompanied by fluorescence detection. Surface chemistry and optical properties of SU-8 microdevices are also examined. SU-8 was shown to exhibit repeatable electroosmotic properties in a wide variety of buffers, and SU-8 microchannels were successfully utilized in peptide and protein analyses without any modification of the native polymer surface. Selected, fluorescent labeled, biologically active peptides were baseline resolved with migration time repeatability of 2.3-3.6% and plate numbers of 112,900-179,800 m(-1). Addition of SDS (0.1%) or SU-8 developer (1.0%) to the separation buffer also enabled protein analysis by capillary zone electrophoresis. Plate heights of 2.4-5.9 microm were obtained for fluorescent labeled bovine serum albumin. In addition, detection sensitivity through SU-8 microchannels was similar to that through BoroFloat glass, when fluorescence illumination was provided at visible wavelengths higher than 500 nm. On the whole, the analytical performance of SU-8 microchips was very good and fairly comparable to that of commercial glass chips as well as that of traditional capillary electrophoresis and chromatographic methods. Moreover, lithography-based patterning of SU-8 enables straightforward integration of multiple functions on a single chip and favors fully microfabricated lab-on-a-chip systems.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17636877     DOI: 10.1021/ac0703956

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  A practical guide for the fabrication of microfluidic devices using glass and silicon.

Authors:  Ciprian Iliescu; Hayden Taylor; Marioara Avram; Jianmin Miao; Sami Franssila
Journal:  Biomicrofluidics       Date:  2012-03-05       Impact factor: 2.800

2.  Shaped apertures in photoresist films enhance the lifetime and mechanical stability of suspended lipid bilayers.

Authors:  Sumit Kalsi; Andrew M Powl; B A Wallace; Hywel Morgan; Maurits R R de Planque
Journal:  Biophys J       Date:  2014-04-15       Impact factor: 4.033

3.  Sacrificial adhesive bonding: a powerful method for fabrication of glass microchips.

Authors:  Renato S Lima; Paulo A G C Leão; Maria H O Piazzetta; Alessandra M Monteiro; Leandro Y Shiroma; Angelo L Gobbi; Emanuel Carrilho
Journal:  Sci Rep       Date:  2015-08-21       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.