Literature DB >> 17635655

Dynamic evaluation of autofocusing for automated microscopic analysis of blood smear and pap smear.

X Y Liu1, W H Wang, Y Sun.   

Abstract

Autofocusing is a fundamental procedure towards automated microscopic evaluation of blood smear and pap smear samples for clinical diagnosis. This paper presents comparison results of 16 selected focus algorithms based on 8000 static bright-field images and 1600 dynamic autofocusing trials using 10 blood smear and pap smear samples. Besides static behaviour, dynamic autofocusing performance is introduced for ranking the 16 focus algorithms. The Fibonacci search algorithm is employed for controlling the z-motor of the microscope to reach the focus position that is determined by focus objective functions. Experimental results demonstrate that the variance algorithm provides the best overall performance. Together with our previously reported findings, it is demonstrated that the variance algorithm or the normalized variance algorithm is the optimal focus algorithm for non-fluorescence microscopy applications including pap smear and blood smear imaging.

Mesh:

Year:  2007        PMID: 17635655     DOI: 10.1111/j.1365-2818.2007.01779.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  5 in total

1.  Compact multi-band fluorescent microscope with an electrically tunable lens for autofocusing.

Authors:  Zhaojun Wang; Ming Lei; Baoli Yao; Yanan Cai; Yansheng Liang; Yanlong Yang; Xibin Yang; Hui Li; Daxi Xiong
Journal:  Biomed Opt Express       Date:  2015-10-14       Impact factor: 3.732

2.  An automated imaging system for radiation biodosimetry.

Authors:  Guy Garty; Alan W Bigelow; Mikhail Repin; Helen C Turner; Dakai Bian; Adayabalam S Balajee; Oleksandra V Lyulko; Maria Taveras; Y Lawrence Yao; David J Brenner
Journal:  Microsc Res Tech       Date:  2015-05-04       Impact factor: 2.769

3.  Parallel implementations to accelerate the autofocus process in microscopy applications.

Authors:  Juan C Valdiviezo-N; Francisco J Hernandez-Lopez; Carina Toxqui-Quitl
Journal:  J Med Imaging (Bellingham)       Date:  2020-01-17

4.  Automated focusing in bright-field microscopy for tuberculosis detection.

Authors:  O A Osibote; R Dendere; S Krishnan; T S Douglas
Journal:  J Microsc       Date:  2010-11       Impact factor: 1.758

5.  FocusALL: Focal Stacking of Microscopic Images Using Modified Harris Corner Response Measure.

Authors:  Madhu S Sigdel; Madhav Sigdel; Semih Dinç; Imren Dinç; Marc L Pusey; Ramazan S Aygün
Journal:  IEEE/ACM Trans Comput Biol Bioinform       Date:  2016 Mar-Apr       Impact factor: 3.710

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.