OBJECTIVES: We sought to provide long-term follow-up data of sirolimus-eluting stents (SES) versus bare-metal stents (BMS) in saphenous vein grafts (SVG) from the RRISC (Reduction of Restenosis In Saphenous vein grafts with Cypher) trial. BACKGROUND: We have previously shown that, in SVG, the use of SES reduces 6-month restenosis and repeated revascularization procedures versus the use of BMS. These data are consistent with trials in native coronary arteries. However, recently published long-term follow-up data of these trials have revealed an increased risk of adverse events (particularly very late stent thrombosis) after SES. METHODS: A total of 75 patients with 96 SVG lesions were randomized to SES versus BMS. All patients underwent clinical follow-up up to 3 years. Specific outcomes assessed in this secondary post-hoc analysis were all-cause mortality, myocardial infarction, and target vessel revascularization. RESULTS:Thirty-eight patients received 60 SES for 47 lesions, whereas 37 patients received 54 BMS for 49 lesions. At a median follow-up time of 32 months (interquartile range 26.5 to 36 months), 11 deaths (7 cardiac, of which 1 was caused by very late stent thrombosis and, 3 were sudden) occurred after SES (29% [95% confidence interval (CI) 17% to 45%]) versus 0 after BMS (0% [95% CI 0% to 9%]) with an absolute difference of 29% ([95% CI 14% to 45%], p < 0.001). The rates of myocardial infarction and target vessel revascularization were not different: 18% and 34% after SES, respectively, versus 5% and 38% after BMS, respectively (p = 0.15 and p = 0.74, respectively). CONCLUSIONS: In this secondary post-hoc analysis, BMS were associated with lower long-term mortality than SES for SVG disease. Also, the 6-month reduction in repeated revascularization procedures with SES was lost at longer-term follow-up. (RRISC Study: Reduction of Restenosis In Saphenous Vein Grafts With Cypher Sirolimus-Eluting Stent; http://clinicaltrials.gov/ct/show/NCT00263263?order=1; NCT00263263).
RCT Entities:
OBJECTIVES: We sought to provide long-term follow-up data of sirolimus-eluting stents (SES) versus bare-metal stents (BMS) in saphenous vein grafts (SVG) from the RRISC (Reduction of Restenosis In Saphenous vein grafts with Cypher) trial. BACKGROUND: We have previously shown that, in SVG, the use of SES reduces 6-month restenosis and repeated revascularization procedures versus the use of BMS. These data are consistent with trials in native coronary arteries. However, recently published long-term follow-up data of these trials have revealed an increased risk of adverse events (particularly very late stent thrombosis) after SES. METHODS: A total of 75 patients with 96 SVG lesions were randomized to SES versus BMS. All patients underwent clinical follow-up up to 3 years. Specific outcomes assessed in this secondary post-hoc analysis were all-cause mortality, myocardial infarction, and target vessel revascularization. RESULTS: Thirty-eight patients received 60 SES for 47 lesions, whereas 37 patients received 54 BMS for 49 lesions. At a median follow-up time of 32 months (interquartile range 26.5 to 36 months), 11 deaths (7 cardiac, of which 1 was caused by very late stent thrombosis and, 3 were sudden) occurred after SES (29% [95% confidence interval (CI) 17% to 45%]) versus 0 after BMS (0% [95% CI 0% to 9%]) with an absolute difference of 29% ([95% CI 14% to 45%], p < 0.001). The rates of myocardial infarction and target vessel revascularization were not different: 18% and 34% after SES, respectively, versus 5% and 38% after BMS, respectively (p = 0.15 and p = 0.74, respectively). CONCLUSIONS: In this secondary post-hoc analysis, BMS were associated with lower long-term mortality than SES for SVG disease. Also, the 6-month reduction in repeated revascularization procedures with SES was lost at longer-term follow-up. (RRISC Study: Reduction of Restenosis In Saphenous Vein Grafts With CypherSirolimus-Eluting Stent; http://clinicaltrials.gov/ct/show/NCT00263263?order=1; NCT00263263).
Authors: P R Stella; G Pavlakis; P Agostoni; H M Nathoe; S Hoseyni Guyomi; B J Hamer; T X Wildbergh; P A Doevendans; E Van Belle Journal: Neth Heart J Date: 2010-10 Impact factor: 2.380
Authors: Ibrahim Akin; Marcus Wiemer; Steffen Schneider; Jochen Senges; Matthias Hochadel; Gert Richardt; Mohamed Abdel-Wahab; Karl-Heinz Kuck; Christoph A Nienaber Journal: Clin Res Cardiol Date: 2011-11-13 Impact factor: 5.460
Authors: Saami K Yazdani; Andrew Farb; Masataka Nakano; Marc Vorpahl; Elena Ladich; Aloke V Finn; Frank D Kolodgie; Renu Virmani Journal: JACC Cardiovasc Interv Date: 2012-06 Impact factor: 11.195
Authors: Pascal Meier; Emmanouil S Brilakis; Roberto Corti; Guido Knapp; Mehdi H Shishehbor; Hitinder S Gurm Journal: PLoS One Date: 2010-06-10 Impact factor: 3.240
Authors: Sun Hong Yoo; Seung Won Jin; Sung Ho Her; Hee Jeoung Yoon; Hyoung Doo Kim; Yun Sun Im; Ki Bae Seung; Jae Hyung Kim Journal: Korean Circ J Date: 2009-06-30 Impact factor: 3.243