Literature DB >> 17630591

The importance of correct norms in blood volume measurement.

Joseph Feldschuh1, Stuart Katz.   

Abstract

Accurate individual norms are required for blood volume measurement to be useful in a clinical setting. The primary physiological determinant of normal blood volume is body composition. Norms have been developed based on weight and body surface area, but these have systematic errors arising from variations in body composition or body size. The only norm that specifically estimates body composition uses deviation from ideal weight. A clinically useful norm must also include a normal range that is sufficiently sensitive and specific. The ultimate test of a norm's effectiveness is how it relates to known physiological factors or outcomes in a clinical or research setting. When tested in relation to outcome results from previously published clinical studies, norms utilizing deviation from ideal weight provide the most accurate categorization of blood volume status.

Mesh:

Year:  2007        PMID: 17630591     DOI: 10.1097/MAJ.0b013e318063c707

Source DB:  PubMed          Journal:  Am J Med Sci        ISSN: 0002-9629            Impact factor:   2.378


  19 in total

Review 1.  Dynamic contrast-enhanced magnetic resonance imaging and pharmacokinetic models in prostate cancer.

Authors:  Tobias Franiel; Bernd Hamm; Hedvig Hricak
Journal:  Eur Radiol       Date:  2010-12-24       Impact factor: 5.315

2.  Total haemoglobin mass but not cardiac volume adapts to long-term endurance exercise in highly trained spinal cord injured athletes.

Authors:  Yorck Olaf Schumacher; Sebastian Ruthardt; Michael Schmidt; Christoph Ahlgrim; Kai Roecker; Torben Pottgiesser
Journal:  Eur J Appl Physiol       Date:  2009-01-06       Impact factor: 3.078

3.  A dosing algorithm for erythropoietin alpha in older adults with heart failure and a preserved ejection fraction.

Authors:  Arman Altincatal; Robert B Macarthur; Sergio Teruya; Stephen Helmke; Mathew S Maurer
Journal:  Cardiovasc Ther       Date:  2011-08-26       Impact factor: 3.023

4.  Correlation of Quantitated Intravascular Volume with Blood Pressure in Patients with Systemic Hypertension.

Authors:  Marat Fudim; Vanessa L Blumer; Renato D Lopes; Patrick Rossignol; Michael Feldschuh; Wayne L Miller; Paul A Sobotka
Journal:  J Cardiovasc Transl Res       Date:  2019-08-28       Impact factor: 4.132

5.  Duration of Retinol Isotope Dilution Studies with Compartmental Modeling Affects Model Complexity, Kinetic Parameters, and Calculated Vitamin A Stores in US Women.

Authors:  Bryan M Gannon; Ashley R Valentine; Christopher R Davis; Julie A Howe; Sherry A Tanumihardjo
Journal:  J Nutr       Date:  2018-08-01       Impact factor: 4.798

6.  Assessment of circulating blood volume with fluid administration targeting euvolemia or hypervolemia.

Authors:  Aaron M Joffe; Nita Khandelwal; Matthew R Hallman; Miriam M Treggiari
Journal:  Neurocrit Care       Date:  2015-02       Impact factor: 3.210

7.  The effect of erythropoietin on exercise capacity, left ventricular remodeling, pressure-volume relationships, and quality of life in older patients with anemia and heart failure with preserved ejection fraction.

Authors:  Rose S Cohen; Paula Karlin; Madeline Yushak; Donna Mancini; Mathew S Maurer
Journal:  Congest Heart Fail       Date:  2010 May-Jun

8.  Treating anemia in older adults with heart failure with a preserved ejection fraction with epoetin alfa: single-blind randomized clinical trial of safety and efficacy.

Authors:  Mathew S Maurer; Sergio Teruya; Bibhas Chakraborty; Stephen Helmke; Donna Mancini
Journal:  Circ Heart Fail       Date:  2012-12-20       Impact factor: 8.790

9.  Measurement of Blood Volume in Adult Rhesus Macaques (Macaca mulatta).

Authors:  Theodore R Hobbs; Steven W Blue; Byung S Park; Jennifer J Greisel; P Michael Conn; Francis K-Y Pau
Journal:  J Am Assoc Lab Anim Sci       Date:  2015-11       Impact factor: 1.232

10.  MRI gadolinium dosing on basis of blood volume.

Authors:  Chia-Ying Liu; Shenghan Lai; João A C Lima
Journal:  Magn Reson Med       Date:  2018-11-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.