Literature DB >> 17630069

Carboxyhemoglobin elevation due to hemolytic anemia.

Neil B Hampson1.   

Abstract

A critically ill man with drug-induced hemolytic anemia and hepatic failure was hospitalized at a private academic medical center in Seattle, Washington. Intravascular hemolysis with associated endogenous carbon monoxide (CO) production resulted in elevation of the patient's carboxyhemoglobin (COHb) level to as high as 9.7%. Serial measurements of the patient's COHb level were obtained and compared with other conventional measures of hemolytic activity. With the availability of new non-invasive measurement technology to detect COHb elevations, emergency clinicians are likely to see COHb elevation as a manifestation of hemolytic anemia.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17630069     DOI: 10.1016/j.jemermed.2006.10.004

Source DB:  PubMed          Journal:  J Emerg Med        ISSN: 0736-4679            Impact factor:   1.484


  7 in total

1.  Assessment of absorbed dose of gamma rays using the simultaneous determination of inactive hemoglobin derivatives as a biological dosimeter.

Authors:  A M M Attia; W M Aboulthana; G M Hassan; E Aboelezz
Journal:  Radiat Environ Biophys       Date:  2019-11-16       Impact factor: 1.925

2.  Continuous Endogenous Exhaled CO Monitoring by Laser Spectrometer in Human EVLP Before Lung Transplantation.

Authors:  Vivien Brenckmann; Raphael Briot; Irène Ventrillard; Daniele Romanini; Maud Barbado; Kevin Jaulin; Candice Trocme; Julien De Wolf; Matthieu Glorion; Édouard Sage
Journal:  Transpl Int       Date:  2022-05-31       Impact factor: 3.842

3.  Elevated carboxyhemoglobin in a marine mammal, the northern elephant seal.

Authors:  Michael S Tift; Paul J Ponganis; Daniel E Crocker
Journal:  J Exp Biol       Date:  2014-05-15       Impact factor: 3.312

4.  Carbon monoxide promotes respiratory hemoproteins iron reduction using peroxides as electron donors.

Authors:  Elena A Sher; Mati Shaklai; Nurith Shaklai
Journal:  PLoS One       Date:  2012-03-12       Impact factor: 3.240

5.  Hemolysis during and after 21 days of head-down-tilt bed rest.

Authors:  Guy Trudel; Hans K Uhthoff; Odette Laneuville
Journal:  Physiol Rep       Date:  2017-12

6.  Endogenous carbon monoxide production in extracorporeal membrane oxygenation-related hemolysis: potential use of point-of-care CO-oximetry carboxyhemoglobin to detect hemolysis.

Authors:  Chan Kai Man; Lam Koon Ngai
Journal:  Clin Case Rep       Date:  2018-01-03

7.  A Comparison of Occupational CO Levels, HbCO, and Lung Functions Between Grill and Non-grill Street Vendors.

Authors:  Noni Novisari Soeroso; Tengku Kemala Intan; Fannie Rizki Ananda
Journal:  Med Arch       Date:  2021-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.