Literature DB >> 17624421

Corrosion behavior of shape memory, superelastic, and nonsuperelastic nickel-titanium-based orthodontic wires at various temperatures.

Deo K Pun1, David W Berzins.   

Abstract

OBJECTIVE: Nickel-titanium orthodontic wires have various temperature-dependent phases. The purpose of this study was to investigate temperature-dependent corrosion characteristics of shape memory, superelastic, and nonsuperelastic orthodontic wires.
METHODS: Four orthodontic wires were investigated: 27 and 40 degrees C copper Ni-Ti (superelastic and shape memory, respectively), superelastic Ni-Ti, and nonsuperelastic Nitinol Classic. Differential scanning calorimetry (DSC) was used to confirm phase/temperature behavior of the wires. Sectioned halves of as-received archwires were assessed electrochemically in artificial saliva at 5, 24, 37, and 45 degrees C. Open circuit potential (OCP) was monitored for 2h followed by polarization resistance and cyclic polarization tests.
RESULTS: DSC results showed Nitinol was primarily martensitic-stable whereas NiTi, 27 degrees C CuNiTi, and 40 degrees C CuNiTi possessed austenite-finish temperatures of approximately 19, 21, and 38 degrees C. The OCP of the CuNiTi wires was significantly greater than NiTi and Nitinol but no apparent trend in values was apparent with regard to temperature or phases present. Corrosion current density (i(corr)) increased with temperature for all wires, but not all were equally influenced. The two lowest austenite-finish temperature wires (27 degrees C CuNiTi and NiTi) approximately tripled in i(corr) from 37 to 45 degrees C. Greater incidence of pitting was observed in the CuNiTi wires. SIGNIFICANCE: This study showed the corrosion rate of various nickel-titanium wires increase with temperature and different phases present may influence corrosion rate trends.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17624421     DOI: 10.1016/j.dental.2007.05.003

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  4 in total

1.  Effect of autoclave sterilization on cyclic fatigue and torsional fracture resistance of NiTi rotary instruments.

Authors:  Wooyoung Kim; Soram Oh; Gil-Joo Ryu; Tae-Hwan Kim; Sung-Jae Kim; Dong-Hyung Kim; Bin-Na Lee; Kee-Yeon Kum; Seok Woo Chang; Ji-Hyun Jang
Journal:  Odontology       Date:  2019-09-11       Impact factor: 2.634

2.  Galvanic coupling of steel and gold alloy lingual brackets with orthodontic wires: Is corrosion a concern?

Authors:  Georgios Polychronis; Youssef S Al Jabbari; Theodore Eliades; Spiros Zinelis
Journal:  Angle Orthod       Date:  2018-03-06       Impact factor: 2.079

3.  Influence of surface layer on mechanical and corrosion properties of nickel-titanium orthodontic wires.

Authors:  Višnja Katić; Helena Otmačić Curković; Damir Semenski; Gorana Baršić; Katarina Marušić; Stjepan Spalj
Journal:  Angle Orthod       Date:  2014-03-21       Impact factor: 2.079

4.  Application of novel anodized titanium for enhanced recruitment of H9C2 cardiac myoblast.

Authors:  Mohaddeseh Behjati; Iman Moradi; Mohammad Kazemi
Journal:  Iran J Basic Med Sci       Date:  2015-09       Impact factor: 2.699

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.