Whole-heart coronary magnetic resonance angiography: contrast-enhanced high-resolution, time-resolved 3D imaging.

Carsten Warmuth1, Jörg Schnorr, Nicola Kaufels, Susanne Wagner, Herbert Pilgrimm, Bernd Hamm, Matthias Taupitz.   

Abstract

OBJECTIVES: To test the feasibility and performance of a 4D magnetic resonance coronary angiography sequence compared with conventional inversion recovery (IR) prepared gradient echo imaging.
MATERIALS AND METHODS: A 4D sequence with 100 milliseconds temporal resolution was implemented on a 1.5 T system. Five minipigs were examined after administration of very small superparamagnetic iron oxide particles. Coronary angiographies with an isotropic resolution of 0.82 mm were performed in the pigs using 4D and IR sequences.
RESULTS: The 4D sequence allowed visualization of the coronary arteries, the effect of their movement and that of the entire heart without prolonging scan time. The contrast-to-noise ratio of the IR images was on average 38% higher than that of the corresponding 4D phase.
CONCLUSIONS: 4D magnetic resonance imaging is superior in that no trigger delay time needs to be determined and an additional whole-heart cine study can be obtained.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17620937     DOI: 10.1097/RLI.0b013e31803c4a5a

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  6 in total

Review 1.  Bioresponsive nanosensors in medical imaging.

Authors:  Eyk Schellenberger
Journal:  J R Soc Interface       Date:  2009-10-21       Impact factor: 4.118

2.  Three-dimensional cine MRI in free-breathing infants and children with congenital heart disease.

Authors:  Achim Seeger; Michael C Fenchel; Gerald F Greil; Petros Martirosian; Ulrich Kramer; Christiane Bretschneider; Joerg Doering; Claus D Claussen; Ludger Sieverding; Stephan Miller
Journal:  Pediatr Radiol       Date:  2009-10-02

3.  Whole heart coronary imaging with flexible acquisition window and trigger delay.

Authors:  Keigo Kawaji; Murilo Foppa; Sébastien Roujol; Mehmet Akçakaya; Reza Nezafat
Journal:  PLoS One       Date:  2015-02-26       Impact factor: 3.240

4.  Contrast-enhanced MR imaging of atherosclerosis using citrate-coated superparamagnetic iron oxide nanoparticles: calcifying microvesicles as imaging target for plaque characterization.

Authors:  Susanne Wagner; Jörg Schnorr; Antje Ludwig; Verena Stangl; Monika Ebert; Bernd Hamm; Matthias Taupitz
Journal:  Int J Nanomedicine       Date:  2013-02-20

5.  The Effect of Inversion Time on the Relationship Between Iron Oxide Nanoparticles Concentration and Signal Intensity in T1-Weighted MR Images.

Authors:  Hodaiseh Saharkhiz; Nahideh Gharehaghaji; Mahmood Nazarpoor; Asghar Mesbahi; Masoud Pourissa
Journal:  Iran J Radiol       Date:  2014-05-15       Impact factor: 0.212

6.  Labeling of mesenchymal stem cells for MRI with single-cell sensitivity.

Authors:  Angela Ariza de Schellenberger; Harald Kratz; Tracy D Farr; Norbert Löwa; Ralf Hauptmann; Susanne Wagner; Matthias Taupitz; Jörg Schnorr; Eyk A Schellenberger
Journal:  Int J Nanomedicine       Date:  2016-04-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.