Literature DB >> 17620812

Computer navigation allows for accurate reduction of femoral fractures.

Yoram A Weil1, Michael J Gardner, David L Helfet, Andrew D Pearle.   

Abstract

Femoral nailing for reduction and stabilization of femoral fractures is a common orthopaedic procedure. However, angular and rotational malalignment is not an infrequent result, and extensive use of fluoroscopy is commonly involved. We tested the accuracy of a computerized navigation system to enhance multiplanar fracture reduction and to decrease the requirement for fluoroscopy. We used a cadaveric femur fixed in a simulator and optically tracked. After obtaining five fluoroscopic images for each reduction attempt, accuracy measurements were taken. We first measured alignment of the intact bone using the navigation system, followed by open and blind reduction of simple and segmental fractures. For the blind, closed reduction trials, the accuracy of restoration of femoral length was 1.2 +/- 0.4 mm (mean +/- standard deviation) for a simple fracture and 1.9 +/- 1.8 mm for a segmental fracture. Rotational accuracy was 1.7 degrees +/- 1.9 degrees and 2.5 degrees +/- 1.8 degrees, respectively. Open reduction using this model yielded no difference between the reduced fracture and the intact bone in coronal and rotational alignment. Computerized navigation has the potential for increasing precision in fracture reduction while minimizing fluoroscopic requirements.

Entities:  

Mesh:

Year:  2007        PMID: 17620812     DOI: 10.1097/BLO.0b013e31804d2355

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  7 in total

1.  Computer-Assisted Orthopedic and Trauma Surgery.

Authors:  Timo Stübig; Henning Windhagen; Christian Krettek; Max Ettinger
Journal:  Dtsch Arztebl Int       Date:  2020-11-20       Impact factor: 5.594

2.  [Femoral nail osteosynthesis. Mechanical factors influencing the femoral antetorsion].

Authors:  M Citak; D Kendoff; M Citak; M J Gardner; M Oszwald; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2008-04       Impact factor: 1.000

3.  Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs: an accuracy and feasibility study.

Authors:  David Hakimian; Amal Khoury; Rami Mosheiff; Meir Liebergall; Yoram A Weil
Journal:  Skeletal Radiol       Date:  2017-11-11       Impact factor: 2.199

4.  [Suitability of computer-assisted femoral intramedullary nailing for control of torsion and length : Systematic review of clinical studies].

Authors:  Emmanouil Liodakis; Christian Krettek; Nael Hawi
Journal:  Unfallchirurg       Date:  2018-03       Impact factor: 1.000

5.  Locked intramedullary femoral nailing without fracture table or image intensifier.

Authors:  Rajesh Rohilla; Roop Singh; Seema Rohilla; Narender K Magu; Ashish Devgan; Ramchander Siwach
Journal:  Strategies Trauma Limb Reconstr       Date:  2011-11-13

6.  Simultaneous use of cannulated reamer and schanz screw for closed intramedullary femoral nailing.

Authors:  Rajesh Rohilla; Roop Singh; Narender K Magu; Ashish Devgan; Ramchander Siwach; Sukhbir Singh Sangwan
Journal:  ISRN Surg       Date:  2011-04-11

7.  3D atlas-based registration can calculate malalignment of femoral shaft fractures in six degrees of freedom.

Authors:  Meghan C Crookshank; Maarten Beek; Michael R Hardisty; Emil H Schemitsch; Cari M Whyne
Journal:  Comput Aided Surg       Date:  2014-04-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.