Literature DB >> 17620511

Preoperative thresholds for pulmonary valve replacement in patients with corrected tetralogy of Fallot using cardiovascular magnetic resonance.

Thomas Oosterhof1, Alexander van Straten, Hubert W Vliegen, Folkert J Meijboom, Arie P J van Dijk, Anje M Spijkerboer, Berto J Bouma, Aeilko H Zwinderman, Mark G Hazekamp, Albert de Roos, Barbara J M Mulder.   

Abstract

BACKGROUND: To facilitate the optimal timing of pulmonary valve replacement, we analyzed preoperative thresholds of right ventricular (RV) volumes above which no decrease or normalization of RV size takes place after surgery. METHODS AND
RESULTS: Between 1993 and 2006, 71 adult patients with corrected tetralogy of Fallot underwent pulmonary valve replacement in a nationwide, prospective follow-up study. Patients were evaluated with cardiovascular magnetic resonance both preoperatively and postoperatively. Changes in RV volumes were expressed as relative change from baseline. RV volumes decreased with a mean of 28%. RV ejection fraction did not change significantly after surgery (from 42+/-10% to 43+/-10%; P=0.34). Concomitant RV outflow tract reduction resulted in a 25% larger decrease of RV volumes. After correction for surgical RV outflow tract reduction, higher preoperative RV volumes (mL/m2) were independently associated with a larger decrease of RV volumes (RV end-diastolic volume: beta=0.41; P<0.001). Receiver operating characteristic analysis revealed a cutoff value of 160 mL/m2 for normalization of RV end-diastolic volume or 82 mL/m2 for RV end-systolic volume.
CONCLUSIONS: Overall, we could not find a threshold above which RV volumes did not decrease after surgery. Preoperative RV volumes were independently associated with RV remodeling and also when corrected for a surgical reduction of the RV outflow tract. However, normalization could be achieved when preoperative RV end-diastolic volume was <160 mL/m2 or RV end-systolic volume was <82 mL/m2.

Entities:  

Mesh:

Year:  2007        PMID: 17620511     DOI: 10.1161/CIRCULATIONAHA.106.659664

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  125 in total

Review 1.  Imaging congenital heart disease in adults.

Authors:  P J Kilner
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

Review 2.  Imaging the right ventricle--current state of the art.

Authors:  Luc L Mertens; Mark K Friedberg
Journal:  Nat Rev Cardiol       Date:  2010-08-10       Impact factor: 32.419

3.  Short- and medium-term outcomes after transcatheter pulmonary valve placement in the expanded multicenter US melody valve trial.

Authors:  Doff B McElhinney; William E Hellenbrand; Evan M Zahn; Thomas K Jones; John P Cheatham; James E Lock; Julie A Vincent
Journal:  Circulation       Date:  2010-07-19       Impact factor: 29.690

4.  4-D flow magnetic-resonance-imaging-derived energetic biomarkers are abnormal in children with repaired tetralogy of Fallot and associated with disease severity.

Authors:  Joshua D Robinson; Michael J Rose; Maria Joh; Kelly Jarvis; Susanne Schnell; Alex J Barker; Cynthia K Rigsby; Michael Markl
Journal:  Pediatr Radiol       Date:  2018-12-01

5.  Tetralogy of Fallot: in good shape?

Authors:  Barbara J M Mulder; Ernst E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2008-12-16       Impact factor: 2.357

6.  Diastolic dysfunction: a new additional criterion for optimal timing of pulmonary valve replacement in adult patient with tetralogy of Fallot?

Authors:  Barbara J M Mulder; Hubert W Vliegen; Ernst E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2008-07-24       Impact factor: 2.357

Review 7.  Valvular heart disease in congenital heart disease: a narrative review.

Authors:  Joshua M Saef; Joanna Ghobrial
Journal:  Cardiovasc Diagn Ther       Date:  2021-06

Review 8.  Will catheter interventions replace surgery for valve abnormalities?

Authors:  Michael L O'Byrne; Matthew J Gillespie
Journal:  Curr Opin Cardiol       Date:  2014-01       Impact factor: 2.161

9.  Management of pulmonic regurgitation and right ventricular dysfunction in the adult with repaired tetralogy of fallot.

Authors:  Elisa Zaragoza-Macias; Karen K Stout
Journal:  Curr Treat Options Cardiovasc Med       Date:  2013-10

10.  Percutaneous pulmonary and tricuspid valve implantations: An update.

Authors:  Robert Wagner; Ingo Daehnert; Philipp Lurz
Journal:  World J Cardiol       Date:  2015-04-26
View more