Literature DB >> 17619991

Laser welding of NiTi orthodontic archwires for selective force application.

P Sevilla1, F Martorell, C Libenson, J A Planell, F J Gil.   

Abstract

Conventional superelastic orthodontic wires are arch-shaped, have the same mechanical properties all along their length and are used to correct the position of teeth. The disadvantage of these archwires is that there are different types of teeth in the mouth and different forces are therefore needed to rectify their position. The aim of this work was to laser weld several types of NiTi orthodontic wires that had different chemical compositions and superelastic properties, in order to adjust their properties to different parts of the mouth. Microstructural changes, transformation stresses and temperatures, variations in corrosion behaviour and ion release were studied in the welded wires.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17619991     DOI: 10.1007/s10856-007-0164-8

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  15 in total

1.  Effect of copper addition on the superelastic behavior of Ni-Ti shape memory alloys for orthodontic applications.

Authors:  F J Gil; J A Planell
Journal:  J Biomed Mater Res       Date:  1999

2.  Passivation of nitinol wire for vascular implants--a demonstration of the benefits.

Authors:  B O'Brien; W M Carroll; M J Kelly
Journal:  Biomaterials       Date:  2002-04       Impact factor: 12.479

3.  Effects of sterilization processes on NiTi alloy: surface characterization.

Authors:  B Thierry; M Tabrizian; O Savadogo; L Yahia
Journal:  J Biomed Mater Res       Date:  2000-01

4.  Ion release from NiTi orthodontic wires in artificial saliva with various acidities.

Authors:  Her-Hsiung Huang; Yu-Hui Chiu; Tzu-Hsin Lee; Shih-Ching Wu; Hui-Wen Yang; Kuo-Hsiung Su; Chii-Chih Hsu
Journal:  Biomaterials       Date:  2003-09       Impact factor: 12.479

5.  In vitro corrosion behavior of 13 prosthodontic alloys.

Authors:  S Canay; M Oktemer
Journal:  Quintessence Int       Date:  1992-04       Impact factor: 1.677

Review 6.  Shape memory alloys for medical applications.

Authors:  F J Gil; J A Planell
Journal:  Proc Inst Mech Eng H       Date:  1998       Impact factor: 1.617

7.  Laboratory and clinical analyses of nitinol wire.

Authors:  G F Andreasen; R E Morrow
Journal:  Am J Orthod       Date:  1978-02

8.  In vitro corrosion measurements of dental alloys.

Authors:  J Geis-Gerstorfer
Journal:  J Dent       Date:  1994-08       Impact factor: 4.379

9.  Inhibition of Ni release from NiTi alloy by hydroxyapatite, alumina, and titanium sputtered coatings.

Authors:  K Ozeki; T Yuhta; H Aoki; Y Fukui
Journal:  Biomed Mater Eng       Date:  2003       Impact factor: 1.300

10.  A clinical trial of alignment of teeth using a 0.019 inch thermal nitinol wire with a transition temperature range between 31 degrees C. and 45 degrees C.

Authors:  G Andreasen
Journal:  Am J Orthod       Date:  1980-11
View more
  7 in total

Review 1.  Laser applications in orthodontics.

Authors:  Somayeh Heidari; Sepideh Torkan
Journal:  J Lasers Med Sci       Date:  2013

2.  Joining characteristics of titanium-based orthodontic wires connected by laser and electrical welding methods.

Authors:  Junko Matsunaga; Ikuya Watanabe; Noriko Nakao; Etsuko Watanabe; Waleed Elshahawy; Noriaki Yoshida
Journal:  J Mater Sci Mater Med       Date:  2015-01-17       Impact factor: 3.896

3.  Corrosion and corrosion-fatigue behavior of cp-Ti and Ti-6Al-4V laser-marked biomaterials.

Authors:  F J Gil; L Delgado; E Espinar; J M Llamas
Journal:  J Mater Sci Mater Med       Date:  2012-02-21       Impact factor: 3.896

4.  Deflection load characteristics of laser-welded orthodontic wires.

Authors:  Etsuko Watanabe; Garrett Stigall; Waleed Elshahawy; Ikuya Watanabe
Journal:  Angle Orthod       Date:  2011-11-01       Impact factor: 2.079

Review 5.  Review of Superelastic Differential Force Archwires for Producing Ideal Orthodontic Forces: an Advanced Technology Potentially Applicable to Orthognathic Surgery and Orthopedics.

Authors:  Michael L Kuntz; Ryan Vadori; M Ibraheem Khan
Journal:  Curr Osteoporos Rep       Date:  2018-08       Impact factor: 5.096

6.  Understanding mechanisms of shape memory function deterioration for nitinol alloy during non-equilibrium solidification by electron beam.

Authors:  Guoqing Chen; Junpeng Liu; Zhibo Dong; Yulong Li; Yuxing Zhao; Binggang Zhang; Jian Cao
Journal:  J Adv Res       Date:  2021-02-25       Impact factor: 10.479

7.  Welding strength of NiTi wires.

Authors:  Tatyane Ribeiro Mesquita; Lídia Parsekian Martins; Renato Parsekian Martins
Journal:  Dental Press J Orthod       Date:  2018 May-Jun
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.