Literature DB >> 1761484

Accuracy of respiratory inductive plethysmograph in measuring tidal volume during sleep.

K F Whyte1, M Gugger, G A Gould, J Molloy, P K Wraith, N J Douglas.   

Abstract

Respiratory inductance plethysmography (RIP) has been widely used to measure ventilation during sleep, but its accuracy in this role has not been adequately tested. We have thus examined the accuracy of the RIP by comparing tidal volume measured with RIP with that measured by a pneumotachograph in eight unrestrained normal subjects during sleep. We have also studied the effect of posture on the accuracy of the RIP. In all sleep stages the correlation between RIP tidal volume measurements and expired volume showed relatively poor correlations (mean r = 0.49-0.60), and the bias of the measurements varied widely. Changes in posture altered the correlations between the two measurements, with no systematic differences between positions. When the subjects resumed a position, the 95% confidence intervals of tidal volume measurement did not overlap the original confidence limits in that posture on 13 of 25 occasions. This study shows that the RIP does not accurately measure tidal volume during sleep in unrestrained subjects and should only be used for semiquantitative assessment of ventilation during sleep.

Mesh:

Year:  1991        PMID: 1761484     DOI: 10.1152/jappl.1991.71.5.1866

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  12 in total

Review 1.  Sleep . 3: Clinical presentation and diagnosis of the obstructive sleep apnoea hypopnoea syndrome.

Authors:  D Schlosshan; M W Elliott
Journal:  Thorax       Date:  2004-04       Impact factor: 9.139

Review 2.  Diagnostic issues in pediatric obstructive sleep apnea.

Authors:  Hiren Muzumdar; Raanan Arens
Journal:  Proc Am Thorac Soc       Date:  2008-02-15

3.  An optimized method for estimating the tidal volume from intracardiac or body surface electrocardiographic signals: implications for estimating minute ventilation.

Authors:  Omid Sayadi; Eric H Weiss; Faisal M Merchant; Dheeraj Puppala; Antonis A Armoundas
Journal:  Am J Physiol Heart Circ Physiol       Date:  2014-06-06       Impact factor: 4.733

4.  Non-invasive respiratory monitoring using long-period fiber grating sensors.

Authors:  M D Petrović; J Petrovic; A Daničić; M Vukčević; B Bojović; Lj Hadžievski; T Allsop; G Lloyd; D J Webb
Journal:  Biomed Opt Express       Date:  2014-03-12       Impact factor: 3.732

5.  Comparison of Apnea Detection Using Oronasal Thermal Airflow Sensor, Nasal Pressure Transducer, Respiratory Inductance Plethysmography and Tracheal Sound Sensor.

Authors:  AbdelKebir Sabil; Martin Glos; Alexandra Günther; Christoph Schöbel; Christian Veauthier; Ingo Fietze; Thomas Penzel
Journal:  J Clin Sleep Med       Date:  2019-02-15       Impact factor: 4.062

6.  Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine.

Authors:  Richard B Berry; Rohit Budhiraja; Daniel J Gottlieb; David Gozal; Conrad Iber; Vishesh K Kapur; Carole L Marcus; Reena Mehra; Sairam Parthasarathy; Stuart F Quan; Susan Redline; Kingman P Strohl; Sally L Davidson Ward; Michelle M Tangredi
Journal:  J Clin Sleep Med       Date:  2012-10-15       Impact factor: 4.062

7.  The impact of obesity on oxygen desaturation during sleep-disordered breathing.

Authors:  Paul E Peppard; Neil R Ward; Mary J Morrell
Journal:  Am J Respir Crit Care Med       Date:  2009-07-30       Impact factor: 21.405

8.  Respiratory rate detection algorithm based on RGB-D camera: theoretical background and experimental results.

Authors:  Flavia Benetazzo; Alessandro Freddi; Andrea Monteriù; Sauro Longhi
Journal:  Healthc Technol Lett       Date:  2014-09-29

9.  Nocturnal thoracoabdominal asynchrony in house dust mite-sensitive nonhuman primates.

Authors:  Xiaojia Wang; Shaun Reece; Stephen Olmstead; Robert L Wardle; Michael R Van Scott
Journal:  J Asthma Allergy       Date:  2010-07-28

10.  Utility of a Smartphone-Based System (cvrPhone) in Estimating Minute Ventilation from Electrocardiographic Signals.

Authors:  Kanchan Kulkarni; Navchetan Awasthi; Jesse D Roberts; Antonis A Armoundas
Journal:  Telemed J E Health       Date:  2021-03-15       Impact factor: 3.536

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.