Literature DB >> 17614742

Performance of an exhaled nitric oxide and carbon dioxide sensor using quantum cascade laser-based integrated cavity output spectroscopy.

Matthew R McCurdy1, Yury Bakhirkin, Gerard Wysocki, Frank K Tittel.   

Abstract

Exhaled nitric oxide (NO) is an important biomarker in asthma and other respiratory disorders. The optical performance of a NOCO(2) sensor employing integrated cavity output spectroscopy (ICOS) with a quantum cascade laser operating at 5.22 microm capable of real-time NO and CO(2) measurements in a single breath cycle is reported. A NO noise-equivalent concentration of 0.4 ppb within a 1-sec integration time is achieved. The off-axis ICOS sensor performance is compared to a chemiluminescent NO analyzer and a nondispersive infrared (NDIR) CO(2) absorption capnograph. Differences between the gas analyzers are assessed by the Bland-Altman method to estimate the expected variability between the gas sensors. The off-axis ICOS sensor measurements are in good agreement with the data acquired with the two commercial gas analyzers. This work demonstrates the performance characteristics and merits of mid-infrared spectroscopy for exhaled breath analysis.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17614742     DOI: 10.1117/1.2747608

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  6 in total

Review 1.  Evolution of clinical and environmental health applications of exhaled breath research: Review of methods and instrumentation for gas-phase, condensate, and aerosols.

Authors:  M Ariel Geer Wallace; Joachim D Pleil
Journal:  Anal Chim Acta       Date:  2018-02-09       Impact factor: 6.558

2.  Laser spectroscopy for atmospheric and environmental sensing.

Authors:  Marc N Fiddler; Israel Begashaw; Matthew A Mickens; Michael S Collingwood; Zerihun Assefa; Solomon Bililign
Journal:  Sensors (Basel)       Date:  2009-12-22       Impact factor: 3.576

3.  Breath analysis using laser spectroscopic techniques: breath biomarkers, spectral fingerprints, and detection limits.

Authors:  Chuji Wang; Peeyush Sahay
Journal:  Sensors (Basel)       Date:  2009-10-19       Impact factor: 3.576

4.  Shot-noise limited Faraday rotation spectroscopy for detection of nitric oxide isotopes in breath, urine, and blood.

Authors:  Yin Wang; Michal Nikodem; Eric Zhang; Frank Cikach; Jarrod Barnes; Suzy Comhair; Raed A Dweik; Christina Kao; Gerard Wysocki
Journal:  Sci Rep       Date:  2015-03-13       Impact factor: 4.379

5.  Fractional Exhaled Nitric Oxide (FENO) in the management of asthma: a position paper of the Italian Respiratory Society (SIP/IRS) and Italian Society of Allergy, Asthma and Clinical Immunology (SIAAIC).

Authors:  Enrico Heffler; Giovanna Elisiana Carpagnano; Elisabetta Favero; Giuseppe Guida; Mauro Maniscalco; Andrea Motta; Giovanni Paoletti; Giovanni Rolla; Eugenio Baraldi; Vincenza Pezzella; Giorgio Piacentini; Stefano Nardini
Journal:  Multidiscip Respir Med       Date:  2020-02-19

Review 6.  Advances in Mid-Infrared Spectroscopy-Based Sensing Techniques for Exhaled Breath Diagnostics.

Authors:  Ramya Selvaraj; Nilesh J Vasa; S M Shiva Nagendra; Boris Mizaikoff
Journal:  Molecules       Date:  2020-05-09       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.