Literature DB >> 17614367

Immunoassay on a power-free microchip with laminar flow-assisted dendritic amplification.

Kazuo Hosokawa1, Masaki Omata, Mizuo Maeda.   

Abstract

We demonstrate a rapid (<30 min) and ultrasensitive (sub-picomolar) immunoassay on a microchip which needs no external power sources for fluid transport. We previously reported a rapid immunoassay of human C-reactive protein (CRP) on the power-free microchip with moderate sensitivity, i.e., a limit of detection (LOD) in sub-nanomolar range, due to the lack of signal amplification. In the current work, we have improved the LOD by 3 orders of magnitude by employing dendritic amplification (DA) methods. Specifically, a sandwich immunocomplex with a biotinylated secondary antibody was constructed on the inner surface of the microchannel as described in the previous report. Onto the immunocomplex, solutions of FITC-labeled streptavidin (F-SA) and biotinylated anti-streptavidin (B-anti-SA) were supplied to grow a dendritic structure. First, we alternately supplied the two solutions for layer-by-layer growth up to three layers. As a result, we obtained an LOD of 0.21 pM with a CRP sample volume of 1.0 microL and assay time of approximately 30 min under an ordinary fluorescence microscope. Second, to reduce the number of incubation steps, we have devised a new DA method: laminar flow-assisted dendritic amplification (LFDA). In this method, F-SA and B-anti-SA were simultaneously and continuously supplied from two laminar streams formed by a Y-shaped microchannel. The immunoassay with the LFDA for 10 min (total assay time of approximately 23 min) with a CRP sample volume of 0.5 microL yielded an LOD of 0.15 pM, which is equivalent to 75 zmol. The combination of the power-free microchip and the LFDA will provide a new opportunity for ultrasensitive point-of-care testing.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17614367     DOI: 10.1021/ac070659o

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  17 in total

1.  A "place n play" modular pump for portable microfluidic applications.

Authors:  Gang Li; Yahui Luo; Qiang Chen; Lingying Liao; Jianlong Zhao
Journal:  Biomicrofluidics       Date:  2012-03-09       Impact factor: 2.800

2.  Systematic characterization of degas-driven flow for poly(dimethylsiloxane) microfluidic devices.

Authors:  David Y Liang; Augusto M Tentori; Ivan K Dimov; Luke P Lee
Journal:  Biomicrofluidics       Date:  2011-06-02       Impact factor: 2.800

3.  Improved porous silicon microarray based prostate specific antigen immunoassay by optimized surface density of the capture antibody.

Authors:  SangWook Lee; Soyoun Kim; Johan Malm; Ok Chan Jeong; Hans Lilja; Thomas Laurell
Journal:  Anal Chim Acta       Date:  2013-07-03       Impact factor: 6.558

4.  Multiplexed cancer biomarker detection using chip-integrated silicon photonic sensor arrays.

Authors:  Adam L Washburn; Winnie W Shia; Kimberly A Lenkeit; So-Hyun Lee; Ryan C Bailey
Journal:  Analyst       Date:  2016-07-12       Impact factor: 4.616

5.  Abstract Book: ISEV2017.

Authors: 
Journal:  J Extracell Vesicles       Date:  2017-05-15

6.  Rapid quantification of disease-marker proteins using continuous-flow immunoseparation in a nanosieve fluidic device.

Authors:  Masumi Yamada; Pan Mao; Jianping Fu; Jongyoon Han
Journal:  Anal Chem       Date:  2009-08-15       Impact factor: 6.986

7.  Integrated acoustic immunoaffinity-capture (IAI) platform for detection of PSA from whole blood samples.

Authors:  A Ahmad Tajudin; K Petersson; A Lenshof; A-M Swärd-Nilsson; L Aberg; G Marko-Varga; J Malm; H Lilja; T Laurell
Journal:  Lab Chip       Date:  2013-05-07       Impact factor: 6.799

8.  An Integrated Centrifugal Degassed PDMS-Based Microfluidic Device for Serial Dilution.

Authors:  Anyang Wang; Samaneh Moghadasi Boroujeni; Philip J Schneider; Liam B Christie; Kyle A Mancuso; Stelios T Andreadis; Kwang W Oh
Journal:  Micromachines (Basel)       Date:  2021-04-23       Impact factor: 2.891

9.  Simple filter microchip for rapid separation of plasma and viruses from whole blood.

Authors:  ShuQi Wang; Dusan Sarenac; Michael H Chen; Shih-Han Huang; Francoise F Giguel; Daniel R Kuritzkes; Utkan Demirci
Journal:  Int J Nanomedicine       Date:  2012-09-17

10.  Sensitive, Color-Indicating and Labeling-Free Multi-Detection Cholesteric Liquid Crystal Biosensing Chips for Detecting Albumin.

Authors:  I-Te Wang; Yen-Hua Lee; Er-Yuan Chuang; Yu-Cheng Hsiao
Journal:  Polymers (Basel)       Date:  2021-05-01       Impact factor: 4.329

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.