Literature DB >> 17613890

Use of microcalorimetry and its correlation with size exclusion chromatography for rapid screening of the physical stability of large pharmaceutical proteins in solution.

Lori Burton1, Rajesh Gandhi, Gerald Duke, Mehdi Paborji.   

Abstract

The utility of microcalorimetry as a rapid screening tool for assessing the solution stability of high molecular weight pharmaceutical proteins was evaluated by using model recombinant antibodies, Protein I and Protein II. Changes in the transition midpoint, T(m), were monitored as a function of pH and/or in the presence of excipients, and results were compared with traditional accelerated stability data from samples that were analyzed by size exclusion chromatography (SEC). The data from microcalorimetry were well correlated with those from SEC for predicting both optimal solution pH as well as excipient effects on solution stability. These results indicate that microcalorimetry can be an efficient screening tool useful in identifying optimal pH conditions and excipients to stabilize pharmaceutical proteins in solution formulations.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17613890     DOI: 10.1080/10837450701212610

Source DB:  PubMed          Journal:  Pharm Dev Technol        ISSN: 1083-7450            Impact factor:   3.133


  4 in total

1.  Biophysical and formulation studies of the Schistosoma mansoni TSP-2 extracellular domain recombinant protein, a lead vaccine candidate antigen for intestinal schistosomiasis.

Authors:  Weiqiang Cheng; Elena Curti; Wanderson C Rezende; Clifford Kwityn; Bin Zhan; Portia Gillespie; Jordan Plieskatt; Sangeeta B Joshi; David B Volkin; Peter J Hotez; C Russell Middaugh; Maria Elena Bottazzi
Journal:  Hum Vaccin Immunother       Date:  2013-07-23       Impact factor: 3.452

2.  Development of a stable low-dose aglycosylated antibody formulation to minimize protein loss during intravenous administration.

Authors:  Sorina Morar-Mitrica; Manasi Puri; Alexandra Beumer Sassi; Joshua Fuller; Ping Hu; George Crotts; Douglas Nesta
Journal:  MAbs       Date:  2015       Impact factor: 5.857

3.  Opposite effects of polyols on antibody aggregation: thermal versus mechanical stresses.

Authors:  Shermeen A Abbas; Vikas K Sharma; Thomas W Patapoff; Devendra S Kalonia
Journal:  Pharm Res       Date:  2011-09-27       Impact factor: 4.200

4.  A High-Throughput MEMS-Based Differential Scanning Calorimeter for Direct Thermal Characterization of Antibodies.

Authors:  Shifeng Yu; Yongjia Wu; Shuyu Wang; Michael Siedler; Peter M Ihnat; Dana I Filoti; Ming Lu; Lei Zuo
Journal:  Biosensors (Basel)       Date:  2022-06-16
  4 in total