The use of titanium non-penetrating clips to close the spinal dura.

J Timothy1, S J Hanna, N Furtado, M Shanmuganathan, A Tyagi.   

Abstract

We present the results of our initial experience in the use of non-penetrating titanium clips in the closure of spinal dura. A retrospective analysis of case notes of patients identified from the unit database was carried out, limited to adults. A proforma that included demographic details, the diagnosis, the procedure undertaken, whether or not additional dural closure methods were used, the use of bed rest and any complications, including cerebrospinal fluid (CSF) leak. There were 58 patients with a mean age of 53 years. The commonest diagnoses were meningioma, ependymoma and neurofibroma. Eight patients had additional methods of dural closure used and approximately half the patients had a period of postoperative bed rest. Eight patients (13.7%) had a CSF leak. Our early experience with the use of non-penetrating clips for the closure of the spinal dura is presented. We have found them easy to use, especially in anatomically-restricted spaces and rapid in their application. However, our results have revealed an unexpectedly high complication rate. A further prospective study to evaluate them more fully is planned.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17612916     DOI: 10.1080/02688690701246210

Source DB:  PubMed          Journal:  Br J Neurosurg        ISSN: 0268-8697            Impact factor:   1.596


  3 in total

Review 1.  The current status and surgical outcome of the minimally invasive techniques for lumbar interbody fusion in India: A systematic review and meta-analysis.

Authors:  Ashutosh Kumar; Jayesh Sardhara; Prabhaker Mishra; Vishwas Kapoor; Anant Mehrotra; Vandan Raiyani; Mayank Singh; Nishant Goyal; Arvind G Kulkarni; Umesh Srikantha; Kamlesh Singh Bhaisora; Kuntal Kanti Das; Arun K Srivastava; Sanjay Behari
Journal:  J Craniovertebr Junction Spine       Date:  2022-09-14

2.  Effectiveness of Repair Techniques for Spinal Dural Tears: A Systematic Review.

Authors:  Elliot H Choi; Alvin Y Chan; Nolan J Brown; Brian V Lien; Ronald Sahyouni; Andrew K Chan; John Roufail; Michael Y Oh
Journal:  World Neurosurg       Date:  2021-02-25       Impact factor: 2.104

3.  Failure Pressures of Dural Repairs in a Porcine Ex Vivo Model: Novel Use of Titanium Clips Versus Tissue Glue.

Authors:  Kevin Chorath; Mason Krysinski; Leonid Bunegin; Jacob Majors; Erik Kent Weitzel; Kevin Christopher McMains; Philip G Chen
Journal:  Allergy Rhinol (Providence)       Date:  2019-09-30