Literature DB >> 17611914

Ultrahigh resolution optical coherence tomography of Barrett's esophagus: preliminary descriptive clinical study correlating images with histology.

Y Chen1, A D Aguirre, P-L Hsiung, S Desai, P R Herz, M Pedrosa, Q Huang, M Figueiredo, S-W Huang, A Koski, J M Schmitt, J G Fujimoto, H Mashimo.   

Abstract

BACKGROUND AND STUDY AIMS: Endoscopic ultrahigh resolution optical coherence tomography (UHR OCT) achieves an axial image resolution of approximately 5 microm, which is 2 - 3 times finer than standard endoscopic OCT imaging. This study investigated the capability of endoscopic UHR OCT for imaging patients with Barrett's esophagus. PATIENTS AND METHODS: Fivty volunteers previously diagnosed with Barrett's esophagus underwent UHR OCT. Imaging was performed at 1.3 microm wavelengths with approximately 5 microm axial and approximately 15 microm transverse resolutions using a 1.8 mm/diameter linear-scanning catheter introduced through the accessory channel of a standard endoscope. OCT images were compared with endoscopic diagnosis and pinch biopsy histological appearances.
RESULTS: UHR OCT images of normal esophagus, Barrett's esophagus, high grade dysplasia and esophageal adenocarcinoma were evaluated. UHR OCT images of the normal esophagus exhibited characteristic layered architecture with uniform epithelium, while images of Barrett's esophagus corresponded to crypt-like glandular structures. High grade dysplasia and esophageal adenocarcinoma images exhibited more heterogeneous structures corresponding to irregular, heterogeneous tissue morphology from distorted and cribriform or villiform glandular architecture. Fine features can be discerned more clearly with endoscopic UHR OCT.
CONCLUSIONS: This study evaluated new endoscopic OCT technology and demonstrated the feasibility of carrying out UHR OCT imaging in conjunction with standard endoscopy for in vivo real-time imaging of Barrett's esophagus, dysplasia, and esophageal adenocarcinoma. A survey of normal and abnormal upper gastrointestinal tissues was performed using a research prototype OCT system with the highest axial resolution to date, and can serve as a baseline for future investigation.

Entities:  

Mesh:

Year:  2007        PMID: 17611914     DOI: 10.1055/s-2007-966648

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  55 in total

1.  Injury depth control from combined wavelength and power tuning in scanned beam laser thermal therapy.

Authors:  Martin Villiger; Andrew Soroka; Guillermo J Tearney; Brett E Bouma; Benjamin J Vakoc
Journal:  J Biomed Opt       Date:  2011-11       Impact factor: 3.170

2.  Quantitative tool for rapid disease mapping using optical coherence tomography images of azoxymethane-treated mouse colon.

Authors:  Amy M Winkler; Photini F S Rice; Rebekah A Drezek; Jennifer K Barton
Journal:  J Biomed Opt       Date:  2010 Jul-Aug       Impact factor: 3.170

Review 3.  Recent advances in optical coherence tomography for the diagnoses of lung disorders.

Authors:  Randy Hou; Tho Le; Septimiu D Murgu; Zhongping Chen; Matt Brenner
Journal:  Expert Rev Respir Med       Date:  2011-10       Impact factor: 3.772

Review 4.  Endoscopic tools for the diagnosis and evaluation of celiac disease.

Authors:  Gianluca Ianiro; Antonio Gasbarrini; Giovanni Cammarota
Journal:  World J Gastroenterol       Date:  2013-12-14       Impact factor: 5.742

5.  Snapshot 3D optical coherence tomography system using image mapping spectrometry.

Authors:  Thuc-Uyen Nguyen; Mark C Pierce; Laura Higgins; Tomasz S Tkaczyk
Journal:  Opt Express       Date:  2013-06-03       Impact factor: 3.894

6.  Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology.

Authors:  Yizheng Zhu; Neil G Terry; John T Woosley; Nicholas J Shaheen; Adam Wax
Journal:  J Biomed Opt       Date:  2011 Jan-Feb       Impact factor: 3.170

7.  Correction of circumferential and longitudinal motion distortion in high-speed catheter/endoscope-based optical coherence tomography.

Authors:  Tan Huu Nguyen; Osman Oguz Ahsen; Kaicheng Liang; Jason Zhang; Hiroshi Mashimo; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2020-12-09       Impact factor: 3.732

8.  Endoscopic optical coherence tomography: technologies and clinical applications [Invited].

Authors:  Michalina J Gora; Melissa J Suter; Guillermo J Tearney; Xingde Li
Journal:  Biomed Opt Express       Date:  2017-04-07       Impact factor: 3.732

9.  Three dimensional mesoscale analysis of translamellar cross-bridge morphologies in the annulus fibrosus using optical coherence tomography.

Authors:  Sang Kuy Han; Chao-Wei Chen; Jerry Wierwille; Yu Chen; Adam H Hsieh
Journal:  J Orthop Res       Date:  2015-01-06       Impact factor: 3.494

10.  Tethered capsule endomicroscopy for microscopic imaging of the esophagus, stomach, and duodenum without sedation in humans (with video).

Authors:  Michalina J Gora; Lucille Quénéhervé; Robert W Carruth; Weina Lu; Mireille Rosenberg; Jenny S Sauk; Alessio Fasano; Gregory Y Lauwers; Norman S Nishioka; Guillermo J Tearney
Journal:  Gastrointest Endosc       Date:  2018-07-19       Impact factor: 9.427

View more