Literature DB >> 17610287

Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques.

Seung Soo Lee1, Jae Ho Byun, Hye-Suk Hong, Seong Ho Park, Hyung Jin Won, Yong Moon Shin, Moon-Gyu Lee.   

Abstract

PURPOSE: To evaluate image quality and accuracy for the detection of focal hepatic lesions depicted on T2-weighted images obtained with two high-resolution free-breathing techniques (navigator-triggered turbo spin-echo [TSE] and respiratory-triggered TSE) and two standard-resolution breath-hold techniques (breath-hold TSE with restore pulse and half-Fourier acquisition single-shot TSE [HASTE]).
MATERIALS AND METHODS: Our institutional review board approved this study, and written informed consent was obtained from all patients. Two readers independently reviewed 200 T2-weighted imaging sets obtained with four sequences in 50 patients. Both readers identified all focal lesions in session 1 and only solid lesions in session 2. The readers' confidence was graded using a scale of 1-4 (1 <or= 50%; 4 >or= 95%). The diagnostic accuracies of the four MR sequences were evaluated using the free-response receiver operating characteristic (ROC) method. Region-of-interest (ROI) measurements were performed for the mean signal intensity (SI) in the liver, spleen, hepatic lesions, and background noise.
RESULTS: The accuracy of navigator-triggered TSE and respiratory-triggered TSE was superior to that of breath-hold TSE with restore pulse and HASTE for the detection of all focal or solid hepatic lesions. The mean lesion-to-liver contrast-to-noise ratio (CNR) of solid lesions in navigator-triggered (P < 0.001) and respiratory-triggered TSE (P < 0.005) was significantly higher than that in HASTE.
CONCLUSION: High-resolution, free-breathing, T2-weighted MRI techniques can significantly improve the detectability of focal hepatic lesions and provide higher lesion-to-liver contrast of solid lesions compared to breath-hold techniques. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17610287     DOI: 10.1002/jmri.21002

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  10 in total

1.  The effect of gadoxetic acid enhancement on lesion detection and characterisation using T₂ weighted imaging and diffusion weighted imaging of the liver.

Authors:  S A Choi; S S Lee; I-H Jung; H A Kim; J H Byun; M-G Lee
Journal:  Br J Radiol       Date:  2010-12-01       Impact factor: 3.039

2.  Quantitative image quality evaluation of MR images using perceptual difference models.

Authors:  Jun Miao; Donglai Huo; David L Wilson
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

Review 3.  MRI of the liver--how to do it.

Authors:  Shreyas S Vasanawala
Journal:  Pediatr Radiol       Date:  2010-04

Review 4.  Magnetic Resonanance Imaging of the Liver (Including Biliary Contrast Agents)-Part 2: Protocols for Liver Magnetic Resonanance Imaging and Characterization of Common Focal Liver Lesions.

Authors:  Andrea Agostini; Moritz F Kircher; Richard K G Do; Alessandra Borgheresi; Serena Monti; Andrea Giovagnoni; Lorenzo Mannelli
Journal:  Semin Roentgenol       Date:  2016-05-30       Impact factor: 0.800

5.  Performance of U-net based pyramidal lucas-kanade registration on free-breathing multi-b-value diffusion MRI of the kidney.

Authors:  Jun Lv; Wenjian Huang; Jue Zhang; Xiaoying Wang
Journal:  Br J Radiol       Date:  2018-03-28       Impact factor: 3.039

Review 6.  Advances in pediatric body MRI.

Authors:  Shreyas S Vasanawala; Michael Lustig
Journal:  Pediatr Radiol       Date:  2011-08-17

7.  Free-Breathing Liver Magnetic Resonance Imaging With Respiratory Frequency-Modulated Continuous-Wave Radar-Trigger Technique: A Preliminary Study.

Authors:  Xinyue Liang; Zhenghong Bi; Chun Yang; Ruofan Sheng; Xinyuan Xia; Zheng Zhang; Yongming Dai; Mengsu Zeng
Journal:  Front Oncol       Date:  2022-06-01       Impact factor: 5.738

8.  Contrast-enhanced free-breathing 3D T1-weighted gradient-echo sequence for hepatobiliary MRI in patients with breath-holding difficulties.

Authors:  C S Reiner; A M Neville; H K Nazeer; S Breault; B M Dale; E M Merkle; M R Bashir
Journal:  Eur Radiol       Date:  2013-06-04       Impact factor: 5.315

9.  T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI.

Authors:  Kyung A Kang; Young Kon Kim; EunJu Kim; Woo Kyoung Jeong; Dongil Choi; Won Jae Lee; Sin-Ho Jung; Sun-Young Baek
Journal:  Korean J Radiol       Date:  2015-08-21       Impact factor: 3.500

10.  The efficacy of the 3-dimensional vibe-caipirinha-dixon technique in the evaluation of pancreatic steatosis

Authors:  Ural Koç; Gökhan Ocakoğlu; Oktay Alğin
Journal:  Turk J Med Sci       Date:  2020-02-13       Impact factor: 0.973

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.