Evaluation of the i-STAT portable clinical analyzer in chickens (Gallus gallus).

Hanspeter W Steinmetz1, Rainer Vogt, Sabine Kästner, Barbara Riond, Jean-Michel Hatt.   

Abstract

The i-STAT portable clinical analyzer (PCA) was evaluated for performance in avian species. With the EG7+ cartridge, which provided results for hydrogen ion concentration, oxygen tension, carbon dioxide tension, sodium, potassium, ionized calcium, hematocrit, and various calculated parameters, analytical accuracy and precision were tested by comparing obtained values to those of established traditional blood gas and chemistry analyzers. Deming's regression and bias plots were used to compare i-STAT results with those obtained by laboratory professionals using benchtop analyzers. The reliability of the i-STAT PCA with EG7+ cartridges was good, with 0-5.7% system failures in measured values. Regression statistics were good for all blood gas analytes and acceptable for electrolytes and calculated parameters, except for potassium and base excess, for which the regression data or the discrepancy between the methods was too large. The system was reliable and easy to use and had an overall acceptable accuracy in avian species. These features, together with portability and small required blood volumes, make the i-STAT suitable for point-of-care use in critical avian patients, although single values require careful interpretation.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17609347     DOI: 10.1177/104063870701900407

Source DB:  PubMed          Journal:  J Vet Diagn Invest        ISSN: 1040-6387            Impact factor:   1.279


  13 in total

1.  Evaluation of the i-STAT (portable clinical analyser) for measuring haematological parameters in Atlantic cod (Gadus morhua) at different CO2 and temperature conditions.

Authors:  Radoslav S Borissov; Sølvi Espeland; Martin H Iversen
Journal:  Fish Physiol Biochem       Date:  2019-10-03       Impact factor: 2.794

2.  Water amino acid-chelated trace mineral supplementation decreases circulating and intestinal HSP70 and proinflammatory cytokine gene expression in heat-stressed broiler chickens.

Authors:  Mikayla F A Baxter; Elizabeth S Greene; Michael T Kidd; Guillermo Tellez-Isaias; Sara Orlowski; Sami Dridi
Journal:  J Anim Sci       Date:  2020-03-01       Impact factor: 3.159

3.  Evaluation of the i-STAT Alinity v in a veterinary clinical setting.

Authors:  Jasper E Burke; Thuy Hien T Nguyen; Tanya Davis; Amie Koenig; Selena L Lane; Jennifer Good; Benjamin M Brainard
Journal:  J Vet Diagn Invest       Date:  2021-05-28       Impact factor: 1.569

4.  Energy Expenditure and Metabolic Changes of Free-Flying Migrating Northern Bald Ibis.

Authors:  Franz Bairlein; Johannes Fritz; Alexandra Scope; Ilse Schwendenwein; Gabriela Stanclova; Gertjan van Dijk; Harro A J Meijer; Simon Verhulst; John Dittami
Journal:  PLoS One       Date:  2015-09-16       Impact factor: 3.240

5.  Effects of Methadone on the Minimum Anesthetic Concentration of Isoflurane, and Its Effects on Heart Rate, Blood Pressure and Ventilation during Isoflurane Anesthesia in Hens (Gallus gallus domesticus).

Authors:  André Escobar; Rozana Wendler da Rocha; Bruno Henri Pypendop; Darcio Zangirolami Filho; Samuel Santos Sousa; Carlos Augusto Araújo Valadão
Journal:  PLoS One       Date:  2016-03-28       Impact factor: 3.240

6.  Midazolam sedates Passeriformes for field sampling but affects multiple venous blood analytes.

Authors:  J Jill Heatley; Jennifer Cary; Lyndsey Kingsley; Hughes Beaufrere; Karen E Russell; Gary Voelker
Journal:  Vet Med (Auckl)       Date:  2015-01-16

7.  Haematology and biochemistry of the San Cristóbal Lava Lizard (Microlophus bivittatus).

Authors:  Randall Arguedas; David Steinberg; Gregory A Lewbart; Diane Deresienski; Kenneth J Lohmann; Juan Pablo Muñoz-Pérez; Carlos A Valle
Journal:  Conserv Physiol       Date:  2018-08-17       Impact factor: 3.079

8.  Health Status of Great Frigatebirds (Fregata minor) Determined by Haematology, Biochemistry, Blood Gases, and Physical Examination.

Authors:  Carlos A Valle; Catalina Ulloa; Diane Deresienski; Cristina Regalado; Juan-Pablo Muñoz-Pérez; Juan Garcia; Britta Denise Hardesty; Alice Skehel; Gregory A Lewbart
Journal:  Conserv Physiol       Date:  2018-07-02       Impact factor: 3.079

9.  Use of portable blood physiology point-of-care devices for basic and applied research on vertebrates: a review.

Authors:  Lauren J Stoot; Nicholas A Cairns; Felicia Cull; Jessica J Taylor; Jennifer D Jeffrey; Félix Morin; John W Mandelman; Timothy D Clark; Steven J Cooke
Journal:  Conserv Physiol       Date:  2014-04-04       Impact factor: 3.079

10.  Commercial Hy-Line W-36 pullet and laying hen venous blood gas and chemistry profiles utilizing the portable i-STAT®1 analyzer.

Authors:  T P Schaal; J Arango; A Wolc; J V Brady; J E Fulton; I Rubinoff; I J Ehr; M E Persia; N P O'Sullivan
Journal:  Poult Sci       Date:  2015-12-25       Impact factor: 3.352