Literature DB >> 17608979

Evaluation of prehospital insertion of the laryngeal mask airway by primary care paramedics with only classroom mannequin training.

Michael J Murray1, Marian J Vermeulen, Laurie J Morrison, Tim Waite.   

Abstract

INTRODUCTION: The laryngeal mask airway (LMAtrade mark airway) provides adequate ventilation and offers a suitable alternative for airway management in patients with cardiac arrest if primary care paramedics do not have intubation skills or are unable to intubate. Training in the use of the LMA usually occurs in the operating room.
OBJECTIVE: To describe the use of the LMA by paramedics in prehospital adult non-traumatic cardiac arrest patients after classroom mannequin training. The study took place in a suburban rural emergency medical service.
METHODS: This is a 2-phase observational study of the effect of paramedic training for LMA insertion using a mannequin and the success rate in the prehospital setting. All paramedics successfully completed classroom mannequin training. All subsequent prehospital adult non-traumatic cardiac arrest patients from mid-February 1999 to Mar. 31, 2000, were eligible. Subjective assessment of chest expansion, ease of ventilation and auscultation defined adequacy of ventilation. Data collected included the number of insertion attempts, reasons for failure, ease of insertion, adverse events and reasons for not attempting intubation. Statistical analysis comprised descriptive frequencies, chi-squared tests for comparison of categorical variables and analysis of variance for continuous variables.
RESULTS: 208 paramedics (100%) successfully completed training. The mean number of attempts was 1, and only 4 (2.1%) paramedics required a second attempt with a mannequin. The paramedics' perception of ease of use comparing the LMA with a bag valve mask (BVM) was evenly distributed across the 3 descriptors: 70 (39%) scored the LMA as easier to use, 57 (31%) as more difficult, and 54 (30%) stated there would be no difference. Of the 291 arrests during the study period, insertion of the LMA was attempted in 283 (97.3%) and was successful in 199 (70%) patients. The LMA became dislodged in 5 (2.5%) cases and was removed in 12 (6%) to clear vomit from the airway. The overall success rate was 182 (64%). The incidence of regurgitation prior to attempted insertion of the LMA was 28% (79 patients). Success rates did not vary significantly with the incidence of vomiting prior to insertion (p = 0.11). The majority of the paramedics evaluated LMA insertion as Very easy 49/220 (22.3%) or Easy 87/220 (39.6%). Paramedic evaluation of ease of use varied with success (p = 0.001).
CONCLUSIONS: This study reports a 100% training success rate with a mannequin and a 64% success with LMA insertion and ventilation in the field by paramedics among adult out-of-hospital non-traumatic cardiac arrest patients.

Entities:  

Year:  2002        PMID: 17608979     DOI: 10.1017/s1481803500007740

Source DB:  PubMed          Journal:  CJEM        ISSN: 1481-8035            Impact factor:   2.410


  7 in total

1.  [Securing the airway in emergencies].

Authors:  Michael Frass
Journal:  Wien Klin Wochenschr       Date:  2008       Impact factor: 1.704

2.  Emergency Neurological Life Support: Airway, Ventilation, and Sedation.

Authors:  Venkatakrishna Rajajee; Becky Riggs; David B Seder
Journal:  Neurocrit Care       Date:  2017-09       Impact factor: 3.210

3.  A comparison of 4 airway devices on cervical spine alignment in cadaver models of global ligamentous instability at c1-2.

Authors:  Adam L Wendling; Patrick J Tighe; Bryan P Conrad; Tezcan Ozrazgat Baslanti; Marybeth Horodyski; Glenn R Rechtine
Journal:  Anesth Analg       Date:  2013-01-25       Impact factor: 5.108

4.  The effects of laryngeal mask airway passage simulation training on the acquisition of undergraduate clinical skills: a randomised controlled trial.

Authors:  Elpiniki Laiou; Thomas H Clutton-Brock; Richard J Lilford; Celia A Taylor
Journal:  BMC Med Educ       Date:  2011-08-11       Impact factor: 2.463

5.  Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin.

Authors:  Gereon Schälte; Christian Stoppe; Meral Aktas; Mark Coburn; Steffen Rex; Marlon Schwarz; Rolf Rossaint; Norbert Zoremba
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2011-10-24       Impact factor: 2.953

Review 6.  Mapping the use of simulation in prehospital care - a literature review.

Authors:  Anna Abelsson; Ingrid Rystedt; Björn-Ove Suserud; Lillemor Lindwall
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2014-03-28       Impact factor: 2.953

7.  Patient safety events in out-of-hospital paediatric airway management: a medical record review by the CSI-EMS.

Authors:  Matthew Hansen; Garth Meckler; William Lambert; Caitlin Dickinson; Kathryn Dickinson; Joshua Van Otterloo; Jeanne-Marie Guise
Journal:  BMJ Open       Date:  2016-11-11       Impact factor: 2.692

  7 in total