Literature DB >> 17608411

Thermostable peroxidase-polylysine films for biocatalysis at 90 degrees C.

Peterson M Guto1, Challa V Kumar, James F Rusling.   

Abstract

Cross-linked films of poly(l-lysine) (PLL) and enzymes covalently linked to surfaces provided remarkable thermostability, enabling biocatalysis at 90 degrees C. Soret spectra, circular dichroism, and voltammetry showed that PLL films containing peroxidases or myoglobin were stable for up to 9 h at 90 degrees C, while the same enzymes in solution denatured completely within 20 min. Biocatalytic reduction of t-BuOOH with enzyme-PLL films, using rotating disk voltammetry, provided Michaelis kcat/Km values. Results showed that horseradish peroxidase (HRP)-PLL is 3-fold more active than soybean peroxidase (SBP)-PLL at 25 degrees C, but SBP-PLL is slightly more active at 90 degrees C. SBP-PLL films had 8-fold larger kcat/Km values at 90 degrees C compared to 25 degrees C. Oxidation of o-methoxyphenol to 3,3'-dimethoxy-4,4'-biphenoquinone by peroxidase-PLL-coated silica colloids gave better yields at 90 degrees C than 25 degrees C, suggesting increasing catalytic efficiency and selectivity at the higher temperature. These biocolloids were reusable with little loss of activity at 90 degrees C.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17608411     DOI: 10.1021/jp071525h

Source DB:  PubMed          Journal:  J Phys Chem B        ISSN: 1520-5207            Impact factor:   2.991


  8 in total

Review 1.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

Review 2.  Biochemical applications of ultrathin films of enzymes, polyions and DNA.

Authors:  James F Rusling; Eli G Hvastkovs; Dominic O Hull; John B Schenkman
Journal:  Chem Commun (Camb)       Date:  2007-08-30       Impact factor: 6.222

3.  Mixed monolayers of ferrocenylalkanethiol and encapsulated horseradish peroxidase for sensitive and durable electrochemical detection of hydrogen peroxide.

Authors:  Yong Peng; Dianlu Jiang; Lei Su; Lin Zhang; Ming Yan; Juanjuan Du; Yunfeng Lu; You-Nian Liu; Feimeng Zhou
Journal:  Anal Chem       Date:  2009-12-15       Impact factor: 6.986

4.  Improved Detection Limit and Stability of Amperometric Carbon Nanotube-Based Immunosensors by Crosslinking Antibodies with Polylysine.

Authors:  Vito Cataldo; Abhay Vaze; James F Rusling
Journal:  Electroanalysis       Date:  2008-01       Impact factor: 3.223

Review 5.  Thin multicomponent films for functional enzyme devices and bioreactor particles.

Authors:  James F Rusling; Dhanuka P Wasalathanthri; John B Schenkman
Journal:  Soft Matter       Date:  2014-11-07       Impact factor: 3.679

Review 6.  Emerging synergy between nanotechnology and implantable biosensors: a review.

Authors:  Santhisagar Vaddiraju; Ioannis Tomazos; Diane J Burgess; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  Biosens Bioelectron       Date:  2009-12-11       Impact factor: 10.618

7.  Biocatalytic anode for glucose oxidation utilizing carbon nanotubes for direct electron transfer with glucose oxidase.

Authors:  Abhay Vaze; Nighat Hussain; Chi Tang; Donal Leech; James Rusling
Journal:  Electrochem commun       Date:  2009-10-01       Impact factor: 4.724

8.  Enhanced catalytic activity and thermal stability of lipase bound to oxide nanosheets.

Authors:  Akane Yamada; Kai Kamada; Taro Ueda; Takeo Hyodo; Yasuhiro Shimizu; Nobuaki Soh
Journal:  RSC Adv       Date:  2018-06-04       Impact factor: 4.036

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.