Literature DB >> 17608334

Treatment of lumbar spinal stenosis with a total posterior arthroplasty prosthesis: implant description, surgical technique, and a prospective report on 29 patients.

Paul McAfee1, Larry T Khoo, Luiz Pimenta, Andy Capuccino, Ahmet Sengoz, Domagoj Coric, Robert Hes, Bart Conix, Farbod Asgarzadie, Azmi Hamzaoglu, Yigal Mirofsky, Yoram Anekstein.   

Abstract

OBJECT: Total disc replacement is an alternative to lumbar fusion, but patients with spinal stenosis, spondylolisthesis, and facet arthropathy are often excluded from this procedure because increased adjacent-segment motion can exacerbate dorsal spondylotic changes. In such cases of degenerative spondylolisthesis with stenosis, decompression and fusion remain the gold standard of treatment. To avoid attendant loss of motion at the treated segment, the TOPS system is a novel total posterior arthroplasty prosthesis that allows for an alternative dynamic, multiaxial, three-column stabilization and motion preservation. The purpose of this study is to report preliminary surgical data and clinical outcomes in patients treated with the TOPS lumbar total posterior arthroplasty system.
METHODS: Twenty-nine patients were enrolled in a nonrandomized, multicenter, prospective pilot study outside the US. All patients had spinal stenosis and/or spondylolisthesis at L4-5 due to facet arthropathy. Radiographs and scores on outcome measures including the visual analog scale (VAS) for pain, Oswestry Disability Index (ODI), Short Form-36, and Zurich Claudication Questionnaire were prospectively recorded before surgery and at 6-week, 3-month, 6-month, and 1-year intervals after surgery. Prior to instrumentation, a bilateral total facetectomy and laminectomy at L4-5 or L3-4 was performed via a standard midline posterior approach. After decompression, the TOPS screws were inserted into four pedicles to achieve maximal purchase with triangulating bicortical trajectories. An appropriately sized TOPS arthroplasty implant was then applied. The mean surgical time was 3.1 hours, and patients' clinical status improved significantly following treatment with the TOPS device. The mean ODI score decreased compared with baseline by 41% at 1 year, and the 100-mm VAS score declined by 76 mm over the same time period. Radiographic analysis showed that lumbar motion was maintained, disc height was preserved, and no evidence of screw loosening was found. No device malfunctions or migrations and no device-related adverse events were reported during the study.
CONCLUSIONS: The TOPS total posterior arthroplasty system represents a novel, dynamic, posterior arthroplasty device that provides multiaxial stability in flexion, extension, rotation, and lateral bending after total facetectomy and neural decompression. The surgical data indicate that it can be safely applied via a traditional approach with low surgical morbidity and excellent 1-year functional and radiographic outcomes in patients with degenerative spondylolisthesis accompanied by stenosis and back pain.

Entities:  

Mesh:

Year:  2007        PMID: 17608334     DOI: 10.3171/foc.2007.22.1.13

Source DB:  PubMed          Journal:  Neurosurg Focus        ISSN: 1092-0684            Impact factor:   4.047


  9 in total

Review 1.  [Status quo of facet joint replacement].

Authors:  K Büttner-Janz
Journal:  Orthopade       Date:  2010-06       Impact factor: 1.087

2.  Elastic resistance of the spine: Why does motion preservation surgery almost fail?

Authors:  Alessandro Landi
Journal:  World J Clin Cases       Date:  2013-07-16       Impact factor: 1.337

3.  We Need to Talk about Lumbar Total Disc Replacement.

Authors:  Stephen Beatty
Journal:  Int J Spine Surg       Date:  2018-08-03

Review 4.  Intervertebral disc degeneration and regeneration: a motion segment perspective.

Authors:  B Ashinsky; H E Smith; R L Mauck; S E Gullbrand
Journal:  Eur Cell Mater       Date:  2021-03-24       Impact factor: 3.942

Review 5.  Current concepts of spondylosis and posterior spinal motion preservation for radiologists.

Authors:  Jack Porrino; Aditya Rao; Jay Moran; Annie Wang; Jonathan Grauer; Andrew Haims; Kimia Kani
Journal:  Skeletal Radiol       Date:  2021-06-15       Impact factor: 2.199

6.  Simple facet joint repair with dynamic pedicular system: Technical note and case series.

Authors:  Ali Fahir Ozer; Tuncer Suzer; Mehdi Sasani; Tunc Oktenoglu; Phillip Cezayirli; Hosein Jafari Marandi; Deniz Ufuk Erbulut
Journal:  J Craniovertebr Junction Spine       Date:  2015 Apr-Jun

7.  Is Degenerative Spondylolisthesis a Contraindication for Total Disc Replacement? Kineflex Lumbar Disc Replacement in 7 Patients With 24-Month Follow-up.

Authors:  Ulrich R Hähnle; Karen Sliwa; Malan de Villiers; Ian R Weinberg; Barry M B E Sweet; Geoffrey P Candy
Journal:  SAS J       Date:  2008-06-01

8.  Change in onset times of the abdominal muscles following functional task in lumbar spinal stenosis.

Authors:  Hyun Seung Song; Seong Doo Park
Journal:  J Exerc Rehabil       Date:  2014-10-31

9.  A short history of posterior dynamic stabilization.

Authors:  Cengiz Gomleksiz; Mehdi Sasani; Tunc Oktenoglu; Ali Fahir Ozer
Journal:  Adv Orthop       Date:  2012-12-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.